![YASKAWA JEPMC-MP2300 User Manual Download Page 257](http://html.mh-extra.com/html/yaskawa/jepmc-mp2300/jepmc-mp2300_user-manual_907070257.webp)
D.3 Monitoring Parameter List
A-25
Appendices
App
D.3 Monitoring Parameter List
OW
54
Servo Driver for
Assistance User
Constant No.
(SERVOPACK
parameter No.for
motion
subcommand)
Set the number of the SERVOPACK parameter number.
Yes
OW
55
Servo Driver for
Assistance User
Constant Size
(SERVOPACK
parameter size for
motion
subcommand)
Set the number of words in the SERVOPACK parameter.
Yes
OL
56
Servo Driver for
Assistance User
Constant Set Point
(SERVOPACK
parameter setting value
for motion
subcommand)
Set the setting for the SERVOPACK parameter.
Yes
OW
58
to OW
5B
−
Reserved for system use.
−
−
OW
5C
Fixed Parameter
Number
Set the number of the fixed parameter to read with the FIXPRM_RD
motion subcommand.
Yes
Yes
OW
5D
−
Reserved for system use.
−
−
OL
5E
Encoder Position
When Power is OFF
(Lower 2 words)
1 = 1 pulse
For linear type, do not set this register.
Yes
OL
60
Encoder Position
When Power is OFF
(Upper 2 words)
1 = 1 pulse
For linear type, do not set this register.
Yes
OL
62
Pulse Position When
Power is OFF
(Lower 2 words)
1 = 1 pulse
For linear type, do not set this register.
Yes
OL
64
Pulse Position When
Power is OFF (Upper 2
words)
1 = 1 pulse
For linear type, do not set this register.
Yes
OL
66 to
OL
6E
−
Reserved for system use.
−
−
OW
70 to
OW
7F
Command Buffer for
Servo Driver
Transmission
Reference Mode
This area is used for command data when MECHATROLINK servo
commands are specified directly.
Yes
(cont’d)
Register No.
Name
Contents
SVB SVR
Register No.
Name
Contents
SVB
SVR
IW
00
RUN Status
Bit 0 Motion Controller Operation Ready
Yes
Yes
Bit 1: Running (At Servo ON)
Yes
Yes
Bit 2: System BUSY
Yes
Bit 3: Servo Ready
Yes
Bit 4: Latch Mode
Yes
Bits 5 to F: Reserved for system use.
−
−
IW
01
Parameter Number
When Range Over
is Generated
Setting parameters: 0 or higher
Fixed Parameters: 1000 or higher
Yes