Machine Protection
6-
39
Machine Protection
This section explains functions for protecting the machine.
Reducing Noise and Leakage Current
The switching frequency of the Drive’s output transistor can be changed to reduce carrier noise and leakage
current from the motor.
Related Parameters
* 1. The setting range depends on the control method of the Drive.
* 2. The factory setting depends on the capacity of the Drive.
* 3. The setting range depends on the capacity of the Drive.
* 4. This parameter can be monitored or set only when 1 is set for C6-01 and F is set for C6-02.
* 5. Displayed in Quick Programming Mode when motor 2 is set for a multi-function input.
Parameter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Operation
Control Methods
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
C6-02
Carrier
Frequency
Selection
Selects the number of pulses per second of
the output voltage waveform. Setting range
determined by C6-01 setting.
0: Low noise
1: Fc = 2.0 kHz
2: Fc = 5.0 kHz
3: Fc = 8.0 kHz
4: Fc = 10.0 kHz
5: Fc = 12.5 kHz
6: Fc = 15.0 kHz
OF: Program (Determined by the settings of
C6-03 thru C6-05)
1 to F
6
*2
No
Q
Q
Q
A
No
*5
CarrierFreq
Sel
C6-03
Carrier
Frequency
Upper Limit
Sets the carrier frequency upper limit and
lower limit in kHz units.
The carrier frequency gain is set as follows:
K is a coefficient that depends on the setting
of C6-03.
C6-03
≥
10.0 kHz: K = 3
10.0 kHz > C6-03
≥
5.0 kHz: K = 2
5.0 kHz > C6-03: K = 1
Maximum carrier frequency allowed when
C6-02 = F.
Note: Carrier frequency is set to C6-03
(upper limit) when operating in Vector
Control Mode.
C6-05 Sets the relationship of output
frequency to carrier frequency when
C6-02 = OF.
2.0
to
15.0
*3 *4
15.0
kHz
*2
No
A
A
A
A
No
CarrierFreq
Max
C6-04
Carrier
Frequency
Lower Limit
0.4
to
15.0
*3 *4
15.0
kHz
*2
No
A
A
No
No
No
CarrierFreq
Min
C6-05
Carrier
Frequency
Proportional
Gain
00
to
99
*4
00
No
A
A
No
No
No
CarrierFreq
Gain
C6-11
Carrier
Frequency
Selection for
Open Loop
Vector 2
Selects the carrier frequency during Vector
Control 2 wo/PG.
1: 2kHz (3-phase modulation)
2: 4kHz (3-phase modulation)
3: 6kHz (3-phase modulation)
4: 8kHz (3-phase modulation)
1 to 4
4
*2
No
No
*5
No
*5
No
*5
No
*5
Q
Carrier Freq
Sel
Carrier frequency
Output frequency x (C6-05) x K
(Max. output frequency)
Output
frequency