30
YASKAWA
TOEPC7106170YB YASKAWA AC Drive GA500 Installation & Primary Operation
Drive Model
Rated Output
Current
(A)
Carrier
Frequency
(kHz)
Drive Watt Loss (W)
Interior Unit
Loss
Heatsink Plate Loss
(P
Loss
)
Total
Loss
4005
5.4
2
16
32
48
4007
7.1
2
20
44
64
4009
8.9
2
28
58
86
4012
11.9
2
39
83
122
4018
17.5
2
58
146
203
4023
23.4
2
81
204
286
4031
31
2
99
259
357
4038
38
2
141
319
460
◆
Screw Sizes and Tightening Torques
shows the correct screw sizes and tightening torques to safety the drive to a
metal surface (enclosure panel).
Table 7.14 Screw Sizes and Tightening Torques
Drive Model
Screw Size
Tightening Torque
N
∙
m (lbf
∙
in)
B001 - B012
M5
2.0 - 2.5
(17.7 - 22.1)
2001 - 2021
M5
2.0 - 2.5
(17.7 - 22.1)
2030 - 2056
M5
2.0 - 2.5
(17.7 - 22.1)
2070
M6
4.0 - 5.0
(35.4 - 44.3)
4001 - 4012
M5
2.0 - 2.5
(17.7 - 22.1)
4018 - 4038
M5
2.0 - 2.5
(17.7 - 22.1)
NOTICE
Damage to Equipment. Tighten the screws to the specified tightening torque.
Incorrect tightening torque can cause too much heat and damage to the drive.