1 General Information and Safety Instructions
YASKAWA Europe
TOEP C710606 75B - AC Drive V1000 IP66 - Quick Start Guide
EN 5
Drive Model Identification
The V1000 IP66 drive type is indicated by the letter “H” in the AC drive model designation code.
General Warnings
The following conventions are used to indicate Safety messages in this manual:
Safety Warnings
W ARNING
• Read and understand this manual before installing, operating or servicing this drive.
• All warnings, cautions, and instructions must be followed.
• All work must be performed by qualified personnel.
• The drive must be installed according to this manual and local codes.
• Heed the safety messages in this manual.
The operating company is responsible for any injuries or equipment damage resulting from failure to heed the warnings in this
manual.
W ARNING
Indicates a hazardous situation, which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a property damage message.
W ARNING
Electrical Shock Hazard
Do not attempt to modify or alter the drive in any way not explained in this manual.
Failure to comply could result in death or serious injury.
YASKAWA is not responsible for any modification of the product made by the user. This product must not be modified.
Never submerge this product in water.
Using this product in water can damage the product and result in serious electric shock.
Do not touch any terminals before the capacitors have fully discharged.
Failure to comply could result in death or serious injury.
Before wiring terminals, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off.
The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait at least five minutes after all
indicators are off and measure the DC bus voltage level to confirm safe level.
Do not allow unqualified personnel to use equipment.
Failure to comply could result in death or serious injury.
Maintenance, inspection, and replacement of parts must be performed only by authorized personnel familiar with installation, adjustment, and
maintenance of AC drives.
C I M R -
Drive
V1000
Series
No.
Region
Code
No.
Voltage Class
B
1-phase, 200-240 Vac
Environmental
Specification
Design
Revision
Order
No.
Customized
Specifications
A
Standard model
3-phase, 380-480 Vac
4
V C B
A
0 0 0 1
H
A
A
C
Europe
No.
Enclosure
Type
H
IP66 with
built in C1
filter
Drives rated current ND [A]
No. User Interface
Digital Operator built-in
- 0 0 8 0
RJ 45 connector only
80
81