INSTALLING ENGINE AND DRIVE UNIT
ZT350 Installation Manual
4-13
Installing the Transom Assembly
12/05
© 2007 Yanmar Marine International
Connecting the Oil Reservoir Hose
1. Connect the quick connector 90° of the gimbal
housing hose assembly to the gimbal housing
fitting.
Figure 4-22
Figure 4-22
1 – Gimbal Housing Hose Assembly
2 – Quick Connector 90°
3 – Gimbal Housing Fitting
CAUTION!
Avoid drive unit damage. The
quick release button on oil reservoir 90° hose
fitting may not lock on gimbal housing if
touching or depressed by connector
(seawater), or plate (seawater inlet) if
equipped. Ensure that the quick release
button NEVER contacts the plate, or
connector if equipped. Failure to do so may
result in a loose 90° fitting, a loss of gear lube
and / or damage to the drive unit.
2. Position the quick release button on the 90°
hose fitting away from the connector
(seawater), or plate (seawater inlet) if equipped.
The release button must not contact the
connector (seawater), or plate (seawater inlet),
if equipped.
Figure 4-23
Figure 4-23
1 – Plate (Seawater Inlet)
2 – ACCEPTABLE Positions
3 – Quick Release Button
4 – NOT ACCEPTABLE Position
5 – Quick Connector 90°
NOTICE: NEVER let the hose come in contact
with the steering system components, the engine
coupler or the drive shaft.
3. The oil reservoir hose assembly can be routed
toward the port side of the engine.
4. Secure the hose assembly at the top side of the
connector (seawater), or plate (seawater inlet),
using the hose J-clip.
Figure 4-24
Figure 4-24
1 – Oil Reservoir Hose
2 – Hose J-Clip
(
3
)
(1)
(2)
0006061
(5)
(1)
(2)
(4)
(
3
)
(
3
)
0006062
(1)
(2)
000606
3