FAILURE DIAGNOSIS
1-214
TNV DI Service Manual
Factor Analysis
14
Rack actuator system
failure
Rack actuator
malfunction due to
excessive hysteresis
etc.
Check rack actuator operation
and hysteresis.
Rack actuator system error:
P1212/4, P1213/3, P1211/7
15
Wire breakage or short-
circuit in harness, or
connector contact
failure
Check error occurrence, tool
data, harness shaking, and
conduction with tester.
Rack actuator system error:
P1212/4, P1213/3, P1211/7
16
Actuator relay system
failure
Contact failure of relay
contact
Check error occurrence, tool
data, impact on relay, and
conduction with tester.
Rack actuator system error:
P1212/4, P1213/3, P1211/7
17
Wire breakage or short-
circuit in relay coil
Check error occurrence, tool
data, impact on relay, and
conduction with tester.
Actuator relay system error:
P1222/4, P1223/3, P1224/2
18
Wire breakage or short-
circuit in harness, or
connector contact
failure
Check error occurrence, tool
data, harness shaking, and
conduction with tester.
Actuator relay system error:
P1222/4, P1223/3, P1224/2
19
Speed sensor system
failure
Reversed polarity of
speed sensor harness
Check polarity difference
between harness drawing and
actual harness.
20
Wire breakage or short-
circuit in speed sensor
Check error occurrence, tool
data, and conduction with
tester.
Speed sensor system error:
P0340/4
21
Wire breakage or short-
circuit in harness, or
connector contact
failure
Check error occurrence, tool
data, harness shaking, and
conduction with tester.
Speed sensor system error:
P0340/4
22
Cooling-water
temperature sensor
system failure
Wire breakage or short-
circuit in cooling-water
temperature sensor
Check error occurrence, tool
data, and conduction with
tester.
Cooling-water temperature
sensor system error: P0117/4,
P0118/3, P0119/2
Occurs only at
low
temperatures.
23
Wire breakage or short-
circuit in harness, or
connector contact
failure
Check error occurrence, tool
data, and conduction with
tester.
Cooling-water temperature
sensor system error: P0117/4,
P0118/3, P0119/2
24
Atmospheric-pressure
sensor system failure
Wire breakage or short-
circuit in atmospheric-
pressure sensor
Check error occurrence, tool
data, and conduction with
tester.
Atmospheric-pressure sensor
system error: P2228/4,
P2229/3, P2230/2
25
Wire breakage or short-
circuit in harness, or
connector contact
failure
Check error occurrence, tool
data, and conduction with
tester.
Atmospheric-pressure sensor
system error: P2228/4,
P2229/3, P2230/2
26
Invalid contact input
signal from working
machine
Working machine
controller failure
Check presence of failure in
working machine controller.
27
Wire breakage or short-
circuit in harness, or
connector contact
failure
Check tool data and
conduction with tester.
No.
Check method
Relevant DTC
Remarks
TNV_DI_SM_A4-Troubleshooting.book 214 ページ 2007年11月15日 木曜日 午後5時27分