I3-6.] Remote control
1) Control cable Use only the single lever remote control device with 1GM 2GM, 3GM and
3HM engines.
Note
The dual lever remote control device cannot be used.
Recommended
Cable
Control Cable
Cable Clamp
Connecting metal
fittings
Speed Control
Morse 33-C
Yanmar Standard
Yanmar Standard
Clutch Control
Morse 33-C
Yanmar Standard
Yanmar Standard
Engine Stop (option)
Yanmar made
Morse
2) Speed control
2-a) A spring is attached to the connector to absorb shock when operating the speed control
lever. Make the wiring so that the spring works when the throttle is "idling" as illustrated.
1. Spring
2. Speed Control Lever
3. Connector
4. Idle adjusting bolt