Yamatake Corporation
ST3000 Smart Transmitter Series 900 Electronic Differential Pressure/Pressure Transmitter
6-49
6-7-15 :Displaying and changing the sealed liquid temperature correc-
tion function
Yamatake’s unique sealed-liquid temperature correction function (patent pending)
minimizes the influence of ambient temperature changes on transmitter performance.
This function implemented by inputting the height between the flanges of the tank on
which the transmitter is mounted. If no inter-flange height is specified in your order,
“Height=0 m” is assumed. In this case, the function is not implemented in your trans-
mitter.
Check and set the sealed liquid temperature correction function using this procedure.
The height between flanges is changed from 1 m, to 2 m, in this example.
Step
Description
SFC screen
1
Press the
key.
2
Press the
key three times.
Or, press the
key four times.
3
Press the
key.
The currently set inter-flange height is
displayed. If the height is 0, the correct-
ing function is not executed.
4
Press the
key.
5
Press the
key.
The inter-flange height for temperature
correction was changed to 2 m.
6
After changing the setting, press the
key twice.
B
CONF
DSTJ CONFIG
CONFORM?
H
NEXT
L
PREV
DSTJ CONFIG
HEIGHT?
ENTER
( Yes )
NON-VOL
DSTJ CONFIG
WORKING...
HEIGHT
5.000 m
W
2
HEIGHT
2 m
ENTER
( Yes )
NON-VOL
HIGHT
WORKING...
CLR
( No )
DSTJ FIT-1234
READY...