![Yamaha XT660 2004 Service Manual Download Page 349](http://html.mh-extra.com/html/yamaha/xt660-2004/xt660-2004_service-manual_946219349.webp)
7 - 5
FI
FUEL INJECTION SYSTEM
Communication error with the meter
30
Lean angle cut-off
switch (latch up
detected)
The motorcycle has over-
turned.
—
No
No
33
Faulty ignition
Open circuit is detected in the
primary lead of the ignition
coil.
—
No
No
41
Lean angle cut-off
switch (open or short
circuit)
Open or short circuit is
detected.
—
No
No
42
Speed sensor, neutral
switch
No normal signals are
received from the speed sen-
sor or an open or short circuit
is detected in the neutral
switch.
• Fixes the gear to the top
gear.
Yes
Yes
43
Fuel system voltage
(monitor voltage)
The ECU is unable to monitor
the battery voltage (open cir-
cuit in the wire to the ECU).
• Fixes the battery voltage
to 12 V.
Yes
Yes
44
Error in writing the
amount of CO adjust-
ment on EEPROM
An error is detected while
reading or writing on
EEPROM (CO adjustment
value).
—
Yes
Yes
46
Vehicle system power
supply (monitor volt-
age)
Power supply to the fuel injec-
tion system relay is not nor-
mal.
—
Yes
Yes
50
ECU internal malfunc-
tion (memory check
error)
Faulty ECU memory. When
this malfunction is detected,
the code number might not
appear on the meter.
—
No
Yes
—
Start unable warning
Relay is not turned ON even if
the crank signal is input while
the start switch is turned ON.
When the start switch is turned
ON while an error is detected
with the fault code of No. 12,
19, 33, 41 or 50.
• Engine trouble warning
light flashes when the start
switch is turned ON.
No
No
Fault
code No.
Item
Symptom
Fail-safe action
Startability
Driveability
Er-1
ECU internal malfunc-
tion (output signal
error)
No signals are received from
the ECU.
—
No
No
Er-2
ECU internal malfunc-
tion (output signal
error)
No signals are received from
the ECU within the specified
duration.
—
No
No
Er-3
ECU internal malfunc-
tion (output signal
error)
Data from the ECU cannot be
received correctly.
—
No
No
Er-4
ECU internal malfunc-
tion (input signal error)
Non-registered data has been
received from the meter.
—
No
No
Fault
code No.
Item
Symptom
Fail-safe action
Startability
Driveability
Summary of Contents for XT660 2004
Page 1: ...2004 XT660R S XT660X S 5VK1 AE1 SERVICE MANUAL ...
Page 3: ......
Page 9: ......
Page 10: ...GEN INFO 1 ...
Page 12: ...GEN INFO ...
Page 24: ......
Page 25: ...SPEC 2 ...
Page 27: ...SPEC ...
Page 80: ...CHK ADJ 3 ...
Page 145: ...CHAS 4 ...
Page 235: ......
Page 236: ...ENG 5 ...
Page 240: ...ENG ...
Page 325: ...COOL 6 ...
Page 327: ...COOL ...
Page 342: ...FI 7 ...
Page 344: ...FI ...
Page 381: ...ELEC 8 ...
Page 387: ...8 4 ELEC CHECKING SWITCH CONTINUITY ...
Page 419: ...8 36 ELEC LIGHTING SYSTEM ...
Page 449: ......
Page 450: ...TRBL SHTG 9 ...
Page 460: ......
Page 461: ......
Page 462: ......