background image

 

TF5/TF3/TF1/TF-RACK/NY64-D Firmware Update Guide

 

 

2

 

 

 Checking the version number 

You can check the TF main firmware and the NY64-D firmware version numbers from the Version field in the 
ABOUT screen of the SYSTEM SETUP screen (V2.5 and earlier)/SETUP screen (V3.0 and later).   

 

 

 Preparing for the update 

The following items are necessary for the update procedure.   

 

Formatted (FAT32) USB flash drive with 1GB free space

 

In the TF series, memory of 4GB or larger will be formatted in FAT32. For the formatting procedure, 
refer to “TF5/TF3/TF1/TF-RACK Reference Manual.” 
For formatting in a computer, refer to documentations supplied with the computer or its OS. 

 

The TF series firmware, and the NY64-D firmware 

Download the latest firmware from the following URL. 

http://www.yamahaproaudio.com/downloads/

 

 

When updating a NY64-D card installed to the TF series: 

There are two options. 

 

Using a USB flash drive inserted to the TF series 

 page 3 

The firmware of the TF series and the NY64-D are separate. You can update them individually, or 
simultaneously.   

 

Using a computer (D

ante Firmware Update Manager) →

 page 7 

Dante Firmware Update Manager is required. 

 

Summary of Contents for TF Series

Page 1: ...while the update is in progress If the update fails and the device still does not operate correctly even after you execute the update once again please contact your Yamaha dealer Yamaha Corporation o...

Page 2: ...matted in FAT32 For the formatting procedure refer to TF5 TF3 TF1 TF RACK Reference Manual For formatting in a computer refer to documentations supplied with the computer or its OS The TF series firmw...

Page 3: ...extracted from the downloaded zip file to the root directory of the USB flash drive Make sure that no other files except those relevant to the TF series and NY64 D firmware are copied to the root dir...

Page 4: ...g the firmware CAUTION DO NOT OPERATE ANY CONTROL OF THE CONSOLE SWITCHES KNOBS FADERS ETC WHILE UPDATING THE FIRMWARE TF series firmware is transferred lasting about two minutes After finishing the f...

Page 5: ...ched 100 completion Done or a message prompting to reboot the TF series appears these are all normal During the update process the display or the LED indicator may turn off This is normal 8 If you nee...

Page 6: ...P ABOUT window The firmware update is now complete NOTE Some firmware versions have new default Presets for Scene or Library To load the new Presets the Initialize All Memories operation is required R...

Page 7: ...irmware_Update_Manager vX Xen pdf vX X version of the user guide http www yamahaproaudio com Update procedure sequence Make sure to perform the update in the following sequence If you plan to update m...

Page 8: ...tibility of the update files with NY64 D If update files other than NY64 D are applied the device will become inoperable In general do not check the Override Device Matching option If this option is l...

Page 9: ...not boot in the failsafe mode you will need to recover the system by a different procedure see Updating the NY64 D firmware by computer via the Dante Firmware Update Manager Confirming the NY64 D firm...

Page 10: ...uter using an Ethernet cable In some cases an error may occur during recovery if you are going through a network switch Connect the computer with the NY64 D in a one to one connection 4 Turn on the po...

Page 11: ...e NY64 D from the Dante network 3 Connect the Dante PRIMARY connector of the NY64 D to the Ethernet connector on the computer using an Ethernet cable In some cases an error may occur during recovery i...

Page 12: ...TF5 TF3 TF1 TF RACK NY64 D Firmware Update Guide 12 Manual Development Department 2015 Yamaha Corporation Published 1 2017 YJ D0...

Reviews: