TF5/TF3/TF1/TF-RACK/NY64-D Firmware Update Guide
11
Dante Controller, and if the device name is shown in black, it is safe to turn off the power.
8. Update the NY64-D firmware.
After recovery, the NY64-D firmware will need to be updated to the latest version. To do this, follow the
instructions on page 7.
The recovery is now complete.
■
Recovery of the NY64-D (without the failsafe mode)
Described below are the procedures to recover the NY64-D which could not be booted in the failsafe mode.
1. Turn off the power to the TF series console to which the NY64-D is installed.
2. Separate the NY64-D from the Dante network.
3. Connect the Dante [PRIMARY] connector of the NY64-D to the Ethernet connector on the computer using
an Ethernet cable.
In some cases, an error may occur during recovery if you are going through a network switch. Connect the
computer with the NY64-D in a one-to-one connection.
4. Turn on the power to the TF series console having the NY64-D.
5. Disable all but one of the network interfaces on your computer.
You should also disable the wireless LAN.
6. Execute the Dante Firmware Update Manager to use failsafe recovery.
In this recovery procedure, make sure that “Override Device Matching” is checked.
For more detailed instructions, refer to step 9 (“Using the failsafe recovery”) of the Dante Firmware Update
Manager User Guide.
The recovery is now complete.