45
RSio64-D
1-5. Settings and starting of DIP switch and UNIT ID switch
* Turn off the power when setting the DIP switch.
If the power is turned on, no setting will be reflected.
•
Make settings for the DIP switch and UNIT ID switch of RSio64-D (Subject to test).
1) DIP switch is set as diagnostic mode.
Dip Switch 3, 7, 8
g
on , Others
g
off
2) ID switch is set as 2.
3) Power switch of RSio64-D is turned on.
89A
B
C
D
EF0
12
3
4
5
67
ON
1 2 3 4 5 6 7 8
UNIT ID switch
DIP switch
•
Make settings for the DIP switch and UNIT ID switch of RSio64-D (Set to test jig mode).
1) DIP switch is set as diagnostic mode.
Dip Switch 3, 7, 8
g
on , Others
g
off
2) ID switch is set as B (Test jig mode).
3) Power switch of RSio64-D is turned on.
89A
B
C
D
EF0
12
3
4
5
67
ON
1 2 3 4 5 6 7 8
DIP switch
UNIT ID switch
It checks having started in diagnostic mode because green LEDs all lighting.
The LED circuit has broken when green LEDs do not all lighting.