G. Troubleshooting
G.4
There are two Fault Indicator Lights on the Generator Control Panel: Overload
Alarm Light and Oil Alert Light.
See
Exhibit 2
and
Exhibit 6
•
Overload Alarm Light blinks rapidly when the Generator is less than five percent (5%)
overloaded
o
Generator will continue running and outputting electricity
•
Overload Alarm Light stays on continuously when the Generator is more than five percent
(5%) overloaded
o
Generator will keep running but the Generator output will be cut off automatically
within twenty (20) seconds
•
Overload Alarm Light stays on when the Generator is faulty (
i.e
. short circuit, low voltage,
over voltage, engine over speed, etc.)
o
Generator will keep running but the Generator output will be automatically cut off
•
Oil Alert Light blinks when the oil level is too low
.
I
n this case
,
the engine will shut down
automatically
and t
he Oil Alert Light
will remain
illuminated.