G. Troubleshooting
Generator
will not
start
:
G.
1
Generator does not crank
•
Inspect battery voltage and connection
to
ensure adequate voltage and secure connections
o
if you have a low battery or poor connections
,
Generator will not turn over
•
Inspect the Master 12Volt Power "ON/OFF" Switch and verify it is in the "ON" position. See
Exhibit 2
o
if battery voltage is adequate and Master 12Volt Power Switch is in the "ON" position
Attempt to start from another starting option
I
f generator still will not crank, manually turn Automatic Choke to "FULL" and
use
pull start to start the Generator. See
Exhibit 2
If still wont start, contact your dealer or NPS directly
G.2
Generator cranks but does not fire
•
Inspect for adequate fuel
o
if fuel is
depleted
or shut off it will not start
•
Inspect for spark
o
if your spark plug
has
carbon buildup, is fuel saturated
or
if
ignition wire is damaged
/
disconnected
, it will not start
•
If generator has fuel and spark
plug is
intact and working properly and it still will not start
,
then
contact your dealer or NPS directly
G.
3
Generator is running but not powering my RV
•
Check 30 amp breakers on the generator to
see if they have
tripped
.
I
f tripped
, then
reset
o
if
they
will not reset
,
then
contact your dealer or
NPS
•
Check circuit breaker
on Control Module (
See
Exhibit 6
)
to see if it
ha
s tripped
.
I
f tripped
,
then
reset
o
if it will not reset
, then
contact your dealer or
NPS
•
Inspect the breakers and GFCI inside the RV
to see if they have tripped.
I
f tripped
, then
reset
o
if
they will not
reset or still
will not
power
, then
contact your dealer
or NPS
NPS offers full support for service, warranty and technical assistance through
www.NPSrvpower.com or 1-866-407-1727 during normal business hours (9:00 am
-
5:00pm
MST) if assistance is requested outside normal business hours, leave a message or send an
email and a team member will assist you as soon as possible.
Page 23 of 30
Rev 1.7