6-4
COOL
2. Measure:
•
Filler cap opening pressure
Cap opens with a pressure below the specified
pressure
→
Replace.
Cap opening pressure:
95 ~ 125 kPa
(0.95 ~ 1.25 kg/cm
2
, 14 ~ 18 psi)
Measurement steps:
•
Attach the cooling system tester
1
to the coolant
filler cap
2
.
Cooling system tester:
90890-01325, YU-24460-01
•
Apply the specified pressure for 10 seconds and
make sure there is no pressure drop.
INSTALLATION
1. Install:
•
Heat exchangers
Use the rivet gun.
SEA6050
HEAT EXCHANGER