i88X
50
INSPECTIONS
Test Item List
Test Number Item, Measuring Requirements etc.
T01
FS,Jitter, mLAN ACTIVE LED Check
T02
MIDI IN/OUT Check
T03
OPTICAL IN/OUT Check
T04
HiZ Check
T05
MIC Check
T06
ANALOG INPUT/OUTPUT, UNLOCK Check
T07
COAXIAL INPUT/OUTPUT Check
T08
ADAT 96KHz INTPUT/OUTPUT Check
T09
ADAT 48KHz INTPUT/OUTPUT Check
T10
ATSC2 CLOCK Check
T11
Factory Set
Measuring Requirements
When executing this test program, the following measuring instruments etc. are required.
Instruments:
•
Digital Audio Analyzer (ATS-2) or the equivalent
•
Oscilloscope ( Input Impedance: more than 1M ohm )
•
DC/AC Current Meter ( Internal Resistance: 0.1 ohm or less)
Others:
•
Player with analog outputs ( Balance/Unbalance )
•
Keyboard Amplifier ( KS15 or the equivalent )
•
01V96(Uses MIDI Test*
1
and ADAT Test), MIDI Monitor
•
PC (Refer to the P42 SOFTWARE ONLY FOR THE mLAN INSPECTION), Optical Input/Output Device etc.
*
1
It is possible to substitute it with MIDI Monitor.
Measuring Conditions:
•
It is time when the value of the Noise level, crosstalk, and the Distortion Rate used 20KHz LPF of measuring
instrument ATS-2 and it is regulated.
•
Input Signal for Test: Sine wave of 1KHz(RS=150 ohm)(Distortion Rate: 0.001% or less), unless otherwise speci-
fied.
•
Load Conditions of Analog Input/Output plug for Test:
CH1 & CH2: Input Termination Resistance : 150 ohm (between Hot and Cold)
CH1-CH8 : Output Load Resistance :
10K ohm (between Hot and Cold)
PHONES : Output Load Resistance :
33 ohm