7-33
E
–
+
ELEC
STARTER MOTOR
SERVICE POINTS
Armature inspection
1. Check:
• Armature shaft
1
Damage/wear
→
Replace.
1
2. Check:
• Commutator
Dirt
→
Clean with 600 grit sandpaper.
3. Measure:
• Commutator diameter
Out of specification
→
Replace.
Minimum commutator diameter:
27.0 mm (1.06 in)
4. Check:
• Commutator undercut
Contaminants
→
Clean.
NOTE:
Use compressed air to remove all mica and
metal particles.
5. Measure:
• Commutator undercut
Out of specification
→
Replace.
Minimum commutator undercut:
0.2 mm (0.01 in)