TRBL
SHTG
Troubleshooting
9-15
62Y5A11
Electrical systems
9
Symptom: Battery becomes weaker quickly.
• Check the charging system.
Measure the Rectifier Regulator
output peak voltage.
Replace the lighting coil.
Out of specifi-
cation?
Out of specifi-
cation?
Replace the Rectifier Regulator.
No
No
Yes
Yes
Measure the output peak voltage of the lighting coil.
Replace the battery, and then
check the voltage of all electri-
cal equipment on your boat.