TRBL
SHTG
Troubleshooting
9-11
62Y5A11
Bracket unit
9
Symptom: Power trim and tilt unit does not operate.
Listen for the operation sound
of the power trim and tilt relay.
Listen for the operation sound
of the power trim and tilt motor.
Check that the manual valve is
closed.
Check the power trim and tilt
fluid level.
Check the power trim and tilt
motor.
Replace the power trim and tilt
relay.
Close the valve.
Can 12 V be
obtained?
Can 12 V be
obtained?
Can the oper-
ation sound
be heard?
Can the oper-
ation sound
be heard?
Replace the power
trim and tilt relay.
Check for continuity
between the battery,
relays, and switch.
Check the voltage between the
blue (L) lead and green (G)
lead.
Check the voltage between each terminal.
• Between the sky blue (Sb) lead and black (B) lead.
• Between the light green (Lg) lead and black (B) lead.
Is it closed?
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
Continued on next page.
Summary of Contents for F100C
Page 1: ...SERVICE MANUAL 60C 28197 5D 11 290429 F100B F100C ...
Page 52: ...SPEC Specifications 2 17 60C5D11 MEMO ...
Page 162: ...LOWR Lower unit 6 15 60C5D11 Drive shaft and lower case F100B 6 ...
Page 190: ...LOWR Lower unit 6 43 60C5D11 Drive shaft and lower case F100C 6 ...
Page 200: ...LOWR Lower unit 6 53 60C5D11 Shimming F100C 6 ...
Page 209: ...60C5D11 7 2 1 2 3 4 5 6 7 8 9 MEMO Special service tools ...
Page 210: ...BRKT Bracket unit 7 3 60C5D11 Tiller handle 7 ...
Page 212: ...BRKT Bracket unit 7 5 60C5D11 ...
Page 214: ...BRKT Bracket unit 7 7 60C5D11 ...
Page 244: ...BRKT Bracket unit 7 37 60C5D11 Gear pump F100B 7 ...
Page 341: ......
Page 343: ......
Page 344: ...YAMAHA MOTOR CO LTD Printed in the Netherlands Jun 2001 0 5 1 CR F100BET F100CET E ...