56
DVR-700/NS-PSW700/NS-P700
D
VR-70
0/
NS-PSW70
0/NS-P70
0
1 4 - 1 N o P R T
NO ERROR
1 4 - 1 T m p D a x x x x
Digital Amp TAS5342 (IC801, IC802 MAIN P.C.B.) over-temperature.
1 4 - 1 I P R T x x x x x
Digital Amp TAS5342 (IC801, IC802 MAIN P.C.B.) over-current.
1 4 - 1 D c P R T x x x x
Speaker output abnormal DC voltage.
1 4 - 1 P S ̲ 5 S x x x x
Abnormal voltage level. +5SUB (for main microprocessor)
1 4 - 1 P S ̲ 3 0 x x x x
Abnormal voltage level. +30D (for digital amp)
1 4 - 1 P S ̲ 1 5 x x x x
1 4 - 1 P S ̲ 1 2 x x x x
1 4 - 1 P S ̲ 7 i x x x x
1 4 - 1 P S ̲ 5 x x x x x
1 4 - 1 P S ̲ 5 i x x x x
1 4 - 1 P S ̲ 3 x x x x x
1 4 - 1 P S ̲ 1 P 2 x x x
1 4 - 1 S P S ̲ 1 x x x x
1 4 - 1 S P S ̲ 2 x x x x
Abnormal voltage level. +15D, -29VP (for DVR-700)
Abnormal voltage level. +12D, +12A, +10T (for digital amp and analog audio)
Abnormal voltage level. +7i (input of the power regulator for DOCK)
Abnormal voltage level. +5D, +5.3D (for digital circuit)
Abnormal voltage level. +5i (for DOCK)
Abnormal voltage level. +3.3D (for digital circuit)
Abnormal voltage level. +1.2D (for DSP)
Abnormal voltage level. +5D (for DVR-700 digital circuit)
Abnormal voltage level. 6R3V, V+5V, 3R3V (for DVD module P.C.B.)
14. ERROR INFORMATION
The error information is displayed up to latest 4 errors.
When the same error is repeated, it is ignored.
This information is retained until sub-menu 14-5 is selected or EEPROM is initialized.
14-1 to 14-4 ERROR INFORMATION