42
DVR-700/NS-PSW700/NS-P700
D
VR-70
0/
NS-PSW70
0/NS-P70
0
1
2
3
Flashes
Flashes
After a few seconds
Opening message
Main menu display
●
Starting Self-Diagnostic Function in the protection cancel mode
If the protection function works and causes hindrance to trouble diagnostic, cancel the protection function as
described below, and it will be possible to enter the self-diagnostic function mode. (The protection functions other than
the excess current detect function will be disabled.)
With this unit in the standby mode, press the keys on the remote control in the order as shown below.
The self-diagnostic function mode is activated and an opening message (the protection history) appears for a few
seconds followed by the main menu display (1-1 VOL 1).
In this mode, the [SLEEP] segment of the FL display of this unit flashes to indicate that the mode is self-diagnostic
function mode with the protection functions disabled.
CAUTION!
Using this product with the protection function disabled
may cause further damage to this unit.
Use special care for this point when using this mode.