–64–
COOLING SYSTEM
ELEC
:
Tester (+) lead
!
Brown lead
Tester (–) lead
!
Black lead
Thermo unit resistance
80
_
C: 3.4 k
Ω
X
4.0 k
Ω
105
_
C: 1.6 k
Ω
X
1.9 k
Ω
6. Thermo unit
S
Remove the thermo unit from the thermostat
housing.
S
Connect the pocket tester (
Ω
1) to the ter-
mo unit
as shown.
S
Immerse the thermo unit in a container filled
with coolant
.
Make sure the hermo unit terminals do not
get wet.
S
Place a thermometer
in the coolant.
S
Slowly heat the coolant, and then let it cool to
the specified temperature indicated in the
table.
S
Check the thermo unit for continuity at the
temperatures indicated in the table.
Replace the thermo unit.
GOOD
CONDITION
BAD CONDITION
7. Coolant temperature warning light
S
Check the LED for continuity.
CONTINUITY
Replace the meter assembly.
NO CONTINUITY
2
8. Voltage
S
Connect the pocket tester (DC 20 V) to the
meter coupler.
S
Turn the main switch to “ON”.
S
Check the voltage (12 V).
The wiring circuit from the main switch to me-
ter coupler is faulty, repair it.
OUT OF SPECIFICATION
1
1
2
NOTE:
Handle the thermo unit with special care.
Never subject the thermo unit to strong
shocks. If the thermo unit is dropped, re-
place it.
WARNING
MEETS
SPECIFICATION
3
EAS00812