121
01V96
If [TABLE] is selected
If [NRPN] is selected
*1) The second and subsequent STATUS need not be added during
transmission. Reception must be implemented so that reception oc-
curs whether or not STATUS is present.
2.4 PROGRAM CHANGE
(Cn)
Reception
If [Program Change ECHO] is ON, these messages are echoed from MIDI
OUT.
If [Program Change RX] is ON and the [Rx CH] matches, these messages will
be received. However if [OMNI] is ON, they will be received regardless of the
channel. When a message is received, a Scene Memory will be recalled according
to the settings of the [Program Change Table].
Transmission
If [Program Change TX] is ON, this message is transmitted according to the set-
tings of the [Program Change Table] on the [Tx CH] channel when a scene
memory is recalled.
If the recalled scene has been assigned to more than one program number, the
lowest-numbered program number will be transmitted. Transmission to Studio
Manager using Program Change messages will not be performed since there is
no guarantee that the contents of the tables will match. (Parameter Changes will
always be used.)
2.5 TIMING CLOCK
(F8)
Reception
It is used to control effects. This message is transmitted 24 times per quarter
note.
2.6 ACTIVE SENSING
(FE)
Reception
Once this message has been received, the failure to receive any message for an
interval of 400 ms or longer will cause MIDI transmission to be initialized, such
as by clearing the Running Status.
2.7 SYSTEM RESET
(FF)
Reception
When this message is received, MIDI communications will be cleared, e.g., by
clearing the Running Status.
2.8 SYSTEM EXCLUSIVE MESSAGE
(F0)
2.8.1 MIDI MACHINE CONTROL
(MMC)
These messages are transmitted when the Machine Control section of the 01V96
is operated. For details, refer to the MMC specification.
2.8.2 BULK DUMP
This message sends or receives the contents of various memories stored within
the 01V96.
The basic format is as follows.
For DUMP DATA
F0 43 0n 7E cc cc <Model ID> tt mm mm [Data …] cs F7
For DUMP REQUEST
F0 43 2n 7E <Model ID> tt mm mm F7
A unique header (Model ID) is used to determine whether the device is a 01V96.
CHECK SUM is obtained by adding the bytes that follow BYTE COUNT
(LOW) and end before CHECK SUM, taking the binary compliment of this
sum, and then setting bit 7 to 0.
CHECK SUM = (-sum)&0x7F
Reception
This message is received if [Bulk RX] is ON and the [Rx CH] matches the device
number included in the SUB STATUS.
When a bulk dump is received, it is immediately written into the specified
memory.
When a bulk dump request is received, a bulk dump is immediately transmit-
ted.
Transmission
This message is transmitted on the [Tx CH] by key operations in the [MI-
DI]-[BULK DUMP] screen.
A bulk dump is transmitted on the [Rx CH] in response to a bulk dump request.
The data area is handled by converting seven words of 8-bit data into eight
words of 7-bit data.
Conversion from actual data into bulk data
d[0~6]: actual data
b[0~7]: bulk data
b[0] = 0;
for( I=0; I<7; I++){
if( d[I]&0x80){
b[0] |= 1<<(6-I);
}
b[I+1] = d[I]&0x7F;
}
Restoration from bulk data into actual data
d[0~6]: actual data
b[0~7]: bulk data
for( I=0; I<7; I++){
b[0] <<= 1;
d[I] = b[I+1]+(0x80&b[0]);
}
2.8.2.1 Scene memory bulk dump format (compress)
The 01V96 can transmit and receive scene memories in compressed form.
STATUS
1011nnnn Bn
Control change
DATA
0nnnnnnn nn
Control number (0-95, 102-119)
0vvvvvvv vv
Control Value (0-127)
STATUS
1011nnnn Bn
Control change
DATA
01100010 62
NRPN LSB
0vvvvvvv vv
LSB of parameter number
STATUS
1011nnnn Bn
Control change *1
DATA
01100011 63
NRPN MSB
0vvvvvvv vv
MSB of parameter number
STATUS
1011nnnn Bn
Control change *1
DATA
00000110 06
MSB of data entry
0vvvvvvv vv
MSB of parameter data
STATUS
1011nnnn Bn
Control change *1
DATA
00100110 26
LSB of data entry
0vvvvvvv vv
LSB of parameter data
STATUS
1100nnnn Cn
Program change
DATA
0nnnnnnn nn
Program number (0-127)
STATUS
11111000 F8
Timing clock
STATUS
11111110 FE
Active sensing
STATUS
11111111 FF
System reset
n
Device Number
cc cc
DATA COUNT (the number of bytes that
follow this, ending before the checksum)
4C 4D 20 20 38 43 39 33
Model ID
tt
DATA TYPE
mm mm
DATA NUMBER
cs
CHECK SUM
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS
0000nnnn 0n
n=0-15 (Device number=MIDI Channel)
FORMAT No.
01111110 7E
Universal bulk dump
COUNT HIGH
0ccccccc ch
data count = ch * 128 + cl
COUNT LOW
0ccccccc cl
01001100 4C
‘L’
01001101 4D
‘M’
00100000 20
‘ ’
00100000 20
‘ ’
00111000 38
‘8’
01000011 43
‘C’
00111001 39
‘9’
00110011 33
‘3’
DATA NAME
01101101 6D
‘m’
0mmmmmmm mh
m=0-99, 256, 8192(Scene0-99, EDIT
BUFFER, UNDO)
0mmmmmmm ml
Receive is effective 1-99, 256, 8192
Summary of Contents for 01V96
Page 49: ...49 01V96 Pattern side 2NAP V989580 2 1 DCD Circuit Board パターン側 ...
Page 52: ...01V96 52 B B to DCD CN202 FD Circuit Board 2NAP V989450 3 ...
Page 53: ...53 01V96 Pattern side B B to MAIN CN704 2NAP V989450 3 パターン側 ...
Page 56: ...01V96 56 HACOM ADA Circuit Board D D 2NAP V989280 3 1 ...
Page 57: ...57 01V96 Pattern side D D 2NAP V989280 3 1 パターン側 ...
Page 60: ...01V96 60 F F HACOM HA Circuit Board 2NAP V989280 3 1 ...
Page 61: ...61 01V96 F F Pattern side 2NAP V989280 3 1 パターン側 ...
Page 64: ...01V96 64 H H MAIN Circuit Board 2NAP V989160 2 5 ...
Page 65: ...65 01V96 H H Component side 2 layer 2NAP V989160 2 5 部品側 2層 ...
Page 66: ...01V96 66 I I MAIN Circuit Board 2NAP V989160 2 5 ...
Page 67: ...67 01V96 I I Component side 5 layer 2NAP V989160 2 5 部品側 5層 ...
Page 68: ...01V96 68 J J MAIN Circuit Board 2NAP V989160 3 3 ...
Page 69: ...69 01V96 J J Pattern side 2NAP V989160 3 3 パターン側 ...
Page 70: ...01V96 70 K K to MAIN CN701 PNCOM PN1 1 2 2 2 Circuit Board 2NAP V989490 2 2 ...
Page 72: ...01V96 72 L L PNCOM PN1 1 2 2 2 Circuit Board 2NAP V989490 2 2 ...
Page 73: ...73 01V96 L L Pattern side 2NAP V989490 2 2 パターン側 ...
Page 109: ...01V96 109 LED 点灯順序図1 LED 点灯順序図2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 1 2 5 3 4 2 3 4 ...
Page 139: ...01V96 5 410 400 Top view ...