background image

1/2 

 

 

- Preface 

Thank you for purchasing a Yamada Pump. This machine is a portable type oil lubricator to supply lubricant to 
machines and vehicles. The machine is provided with a 110 type air-powered pump on a large cabinet with a capacity 
of 50L, which is most suitable to supply a large volume of oil at a time. 
The machine is also provided with a grip meter with flow meter in the standard specification, which permits grasp the 
oil supply volume accurately. 

 
<Note>

 

This machine, which is designed exclusively for oil, cannot be used for any substance other than lubricant. 

 

-  For Safe Operation 

This manual describes the items that are important for the user to operate this product safely, correctly, and efficiently. 
Before operating this product, read this manual thoroughly, in particular, “Warnings and Cautions” at the beginning of 
this manual. 
 

-  Warnings and Cautions 

For safe use of this product, be sure to note the following: In this document, warnings and cautions are indicated by 
symbols. These symbols are for those who will operate this product and for those who will be nearby, for safe 
operation and for prevention of personal injury and property damage. The following warning and caution symbols 
have the meanings described below. Be sure to remember their meanings. 
 

WARNING 

This indicates the existence of potential hazard which, if not avoided, will 

result in death or serious injury. 

CAUTION : 

This indicates the existence of potential hazard which, if not avoided, may 

result in bodily injury or in physical damage. 

Furthermore, to indicate the type of danger and damage, the following symbols are also used along with those 
mentioned above: 

   

This symbol indicates a DON'T, and will be accompanied by an explanation on something you must not 
do.  

 

This symbol indicates a DO, and will be accompanied by instructions on something you must do in a 
certain situation. 

 

-  Precautions on Use 

The following warnings and cautions are very important. Be sure to observe them. 

WARNING 

-  Some types of oil that you may use may inflame the skin. Read the precautions for handling the oil 

given by the oil maker and handle the oil carefully. 

-  This machine cannot be used for gasoline, light oil, chemicals, solvents, etc. Gasoline is a high-volatility 

fuel. Do not use it to wash the pump in any case. It may cause ignition or explosion. 

-  When operating the machine, electrostatic sparks may give a shock to the human body or cause death 

or bodily injury due to a fire or explosion. Be sure to perform grounding securely by using a grounding 
conductor according to the operating environment. 

 

 

 

 

 

Summary of Contents for SGR-110A5

Page 1: ...IL LUBRICATOR SGR 110A5 MODEL No 880635 WARNING Prior to operating this pump be sure to read this operation manual for safety After reading the manual please keep it at hand any time for your quick re...

Page 2: ......

Page 3: ...nd caution symbols have the meanings described below Be sure to remember their meanings WARNING This indicates the existence of potential hazard which if not avoided will result in death or serious in...

Page 4: ...Any secondary accident such as pollution of installation due to hose damage or leakage from the valve without shutting off the supply air shall be attributable to the user s responsibility During mach...

Page 5: ...hine 3 5 Maintenance and Inspection 5 1 Troubleshooting and Corrective Measures 4 5 2 Maintenance and Inspection 5 6 Disassembly and Assembly 6 1 Disassembling the Air Motor and the Lower Pump 5 6 2 D...

Page 6: ...a lower pump to draw up the material as shown in the figure at right When compressed air is supplied from the compressor to the air motor the air piston starts its up down motion by the function of t...

Page 7: ...ent 1 Turn the knob of the air regulator counterclockwise to reset the indicator of the pressure gauge to 0 After that connect the air chuck to supply air NOTE Using an air regulator permits adjusting...

Page 8: ...rtant machine 1 Before starting oil supply be sure to turn the knob of the grip meter counterclockwise to reset to the 0 position If the short needle has not been reset turn the long needle to reset t...

Page 9: ...any open valve on the material output side Check if the material does not leak at the exhaust port of the air motor The air motor is faulty Ask for servicing the air motor When the outlet side is clo...

Page 10: ...ed directly so its failure rate is very low The air motor does not need to be disassembled If disassembling is required ask the dealer to disassemble the air motor WARNING Gasoline is a high volatilit...

Page 11: ...any blemish or wear is found replace the part with a new one 5 Do not disassemble the housing and the connecting rod if possible If they are disassembled assemble them so that the clearance between t...

Page 12: ...late 1 9 710927 Valve seat 1 10 712018 Cylinder 1 11 683503 Nut 1 12 710912 Valve seat 1 13 712168 Collar 1 14 712175 Adapter 1 15 611101 Bolt 1 No Parts No Description Q ty 1 851755 Pump Assy 1 2 682...

Page 13: ...006 Spacer 15 59310 001 Totalizer Assembly 16 55212 115 Screw Totalizer Frame 17 59008 001 Packing Gland Kit Buna N 18 13268 000 Cam Standard electronic 19 22872 001 Quad Ring Buna N 20 58959 001 Scr...

Page 14: ...elow 480 480 953 SGR 110A5 880635 5 x 1 FLUID CONNECTION DISCHARGE PORT Grip meter AIR CONNECTION SUPPLY PORT Coupler plug PS 20PM 0 3 0 7 MPa 87 5 dB ENV TEMPERATURE 0 60 C MATERIAL TEMP 0 80 C 27 5...

Page 15: ...cause corrosion inflation or dissolution of the component parts of the product 4 Irregularity arising from repair made by other than by our firm our regional office dealer or authorized service perso...

Page 16: ...Hengelo O The Netherlands PHONE 31 0 74 242 2032 FAX 31 0 74 242 1055 Manufactured by YAMADA CORPORATION INTERNATIONAL DEPARTMENT No 1 3 1 Chome Minami Magome Ohta Ku Tokyo 143 8504 Japan PHONE 81 0 3...

Reviews: