14
Reset Key Pad code
If the Key Pad code is accidentally forgotten, the Key Pad
can be reset to factory default (0000) using the following
steps:
1.
Unscrew the two Key Pad case screws and remove Key
Pad back cover (please disable tamper first).
Locate and remove the battery. See battery change
section (16-17)
2.
Press the number ‘4’ key at the same time as reinserting
the battery.
3.
Screw the Key Pad case together and re-learn the Key
Pad into the system using the steps described above in
this section.
Using your Key Pad
• The Key Pad can be used to Away Arm and Home Arm
the system using the buttons as shown.
• The system is disarmed by pressing the disarm button
followed by your PIN code.
• An emergency alarm can be activated by pressing the
panic A and B buttons simultaneously. Deactivate panic
event by pressing the disarm button followed by your PIN
code.
• If there is a system fault, you will need to press the Arm/
Home Arm button for a second time to “force arm” the
system.
Using your Smoke Detector
Smoke Detection
When smoke is detected the device will activate for a
minimum of 10 seconds with a two tone alarm and flashing
LED. The Detector will send a radio signal to the Smart
Hub. You will then be notified via a push notification, SMS
and email .
• Pressing the test button when in an alarm condition will
silence the alarm for 10 minutes. It will automatically
resume smoke detection again after this period.
Testing
• Smoke Detector testing should be done on a regular
monthly basis. Pressing the test button will make the LED
flash, the audible sounder chime and will send a radio
test signal to the Smart Hub when the button is released.
If nothing happens after pressing the test button, it
indicates the batteries will need changing.
Recalibration
• The Smoke Detector might need recalibrating after time
to ensure it is working at its optimum. This is done by
pressing and holding the test button until the LED flashes
and beeps after 10 seconds. The Detector will then start
its self calibration routine.
Using your Panic Button
Activate an Alarm
• Press and hold the red button for at least 3 seconds. The
LED will light momentarily and the alarm will be activated.
Silence an Alarm
1.
Press and hold down the red button for 10 seconds.
The LED will light momentarily for a second time and the
alarm will be silenced.
2.
Please note that silencing the alarm with the Panic
Button does not reset the system. If the alarm is armed
prior to activation, the system will re-arm after being
silenced with the Panic Button.
3.
The system will require a reset at the Smart Hub after
being silenced with the Panic Button.
Using Accessories
(cont.)
7