Table 14. Proc_Cal_012: Aux 3 Dir A Valve Output Threshold (Continued)
Information:
Pressure Method: Perform Actions 1, 2, 3, 4, and 6.
Visual Method: Perform Actions 2, 3, 5, and 6.
Information:
Leave truck running at idle after performing Proc_Cal_002.
Action 1:
With the truck running, note the pressure reading (standby pressure).
Action 2
Activate Lift Control to Position Attachment 0.6 m (2 ft) up
with no load on the forks/attachment. Activate the Aux 3 control to
position the function in the middle of the range.
You Will See:
Main Menu
Passwords
Step 1: Press
or
Until You See:
Main Menu
Calibrations
Step 2: Press
*
One Time
You Will See:
Calibrations
Lift Valve Output
Step 3: Press
or
Until You See:
Calibrations
Aux 3 Output Dir A
Step 4: Press
*
One Time
You Will See:
Aux 3 Output Dir A
Press
*
at Creep
A.
E-HYD CONTROL LEVERS
1.
LIFT/LOWER
DIRECTION LIFT ↓
DIRECTION
LOWER ↑
2.TILT
DIRECTION BACK
↓
DIRECTION FWD
↑
3.
*AUX 1 OR AUX
2
DIRECTION A ↑
DIRECTION B ↓
4.
*AUX 2 OR AUX
3
DIRECTION A ↑
DIRECTION B ↓
5.
*FOURTH
LEVER
6.
*THIRD LEVER
7.
SEAT ARMREST
*AUX 2 IS IN THE FOURTH LEVER LOCATION EXCEPT AS FOLLOWS: WITH 5 FUNCTION VALVE WITH CLAMPING ATTACHMENT,
AUX 2 IS IN THE THIRD LEVER LOCATION.
8000 YRM 1134
Proc_Cal_012: Aux 3 Dir A Valve Output Threshold
Confidential/Proprietary - Do Not Copy or Duplicate
35