Table 14. Proc_Cal_012: Aux 3 Dir A Valve Output Threshold (Continued)
2.
JOYSTICK
1.
TILT BACK
2.
AUX 1
DIRECTION A ↑
DIRECTION B ↓
3.
LIFT ↓
4.
↑ LOWER
5.
AUX 2
DIRECTION A ↑
DIRECTION B ↓
6.
TILT FORWARD
7.
SEAT ARMREST
Action 3:
SLOWLY Activate (Feather) Aux 3 Dir A Control.....
NOTE:
Optional for initial manufacture: Use the same pressure setting for both Dir A and Dir B of this function to
provide uniform flow outputs.
Action 4:
Until the pressure is just above the standby pressure (as the needle moves on an analog gage). Note
that the pressure reading may oscillate. Hold control steady and.....
Action 5:
WATCH for Attachment Movement. When it first starts to move slowly, HOLD control steady and.....
Press
*
One Time while holding the control.
Action 6:
STOP activating the Aux 3 Dir A Control. LOOK at the display.
Go to the Calibration Step below that matches your display.
If You See.....
Result out of range
Repeat Calibration
Press
*
One Time
You Will See:
Aux 3 Valve Output
Dir A
Press
*
at Creep
Return to Action 3.
Pressure Method: Perform Actions 3, 4, and 6 again.
Visual Method: Perform Actions 3, 5, and 6 again.
If You See.....
Aux 3 Valve Output Dir B
Press
*
at Creep
To Continue with Calibrations.....
Go to Action 3 of Proc_Cal_013.
To Quit and Save....
Step 1: Press
or
Until You See:
Aux 3 Valve Output
Dir B
Back 1 Level
Step 2: Press
*
One Time
You Will See:
Calibrations
Back 1 Level
Perform Proc_Cal_003: Save and Exit.
Proc_Cal_012: Aux 3 Dir A Valve Output Threshold
8000 YRM 1134
36
Confidential/Proprietary - Do Not Copy or Duplicate