Table 20. Proc_Cal_016B: Transmission Valve Calibration (Continued)
NOTE:
Keep park brake applied, full service brake applied, and
full accelerator applied during entire time that automated transmis-
sion valve calibration is occurring. If you release the service brake
at any time during L2 calibration, the calibration will start over from
the beginning.
Press
*
One Time
You Will See:
Xmsn Oil Temp
xxx°
Watch display countdown. When completed successfully.....
The engine will go to idle and you will see for approximately 5 mi-
nutes:
You Will See:
Calibrate Xmsn Valve
Xmsn Calibration 0
Watch display. When completed successfully.....
You will see
for approximately 5 minutes:
You Will See:
Calibrate Xmsn Valve
Xmsn Calibration 1
Watch display. When completed successfully.....
You will see
for approximately 5 minutes:
You Will See:
Calibrate Xmsn Valve
Xmsn Calibration 2
Watch display. When completed successfully.....
You will see
for approximately 5 minutes:
You Will See:
Calibrate Xmsn Valve
Xmsn Calibration 3
Watch display. When completed successfully.....
You will see
for approximately 5 minutes:
You Will See:
Calibrate Xmsn Valve
Xmsn Calibration 4
Watch display. When completed successfully.....
You Will See:
Calibrations
Calibrate Xmsn Valve
Perform Proc_Cal_003: Save and Exit.
8000 YRM 1134
Proc_Cal_016B: Trans. Valve Calibration-Electronic and Electronic Extended