![Yaesu ZCUT-9GR Instruction Manual Download Page 12](http://html1.mh-extra.com/html/yaesu/zcut-9gr/zcut-9gr_instruction-manual_892781012.webp)
OIL HOLES
BE CAREFUL TO HANDLE
THE SENSORS
EXTREME CARE
OF BLADE
OIL HOLES
LOWER BLADE GUIDE
①
③
INSTALL BLADE UNIT
②
REMOVE BLADE UNIT
Whenever you clean or replace the BLADE UNIT,
do not touch the sharp edge of the blade.
Only Blade is not accepted to be replaced.
It needs to change with the whole Blade Unit.
◆
Turn the POWER SWITCH off.
◆
Remove the BLADE UNIT by releasing the BLADE UNIT RELEASE LEVER.
◆
Install the new BLADE UNIT into the body.
◆
Push down on the housing firmly until it is locked.
Make sure that the lower blade is positioned properly, turn the BLADE
UNIT over and take a look the bottom edge of the lower blade.
Clean the Blade Unit
When cutting tapes with heavy adhesive, the residue will remain on the
blade gradually.
It is necessary to remove the BLADE UNIT for cleaning.
◆
Turn the POWER SWITCH off.
◆
Remove the BLADE UNIT by releasing BLADE UNIT RELEASE LEVER.
◆
Put some alcohol on a clean dry cloth, or use a swab to remove the residue.
◆
Replace the BLADE UNIT.
Lubricate the Blade
Lubricate the blade in order to prevent residue stick on the blade.
◆
Turn the POWER SWITCH off.
◆
Remove the BLADE UNIT from the body.
◆
Locate three oil holes on the back side of the top blade.
◆
Drip one drop of BLADE OIL into each hole.
◆
Also lubricate LOWER BLADE GUIDE.
◆
Do not lubricate over and over again.
Wipe the spare oil away by using cotton cloth.
◆
Replace the BLADE UNIT into the body.
◆
Turn the POWER SWITCH on.
Make several test cuts in order to make sure the tape will not fall down
from the TAPE OUTLET.
Clean the Sensors
There are two pairs of SENSORS below the TAPE OUTLET.
If the opening is covered by tape residue or debris, the SENSORS will
not detect the presence tape.
Always keep clean around the SENSORS.
To protect the SENSOR, clean the openings after removed the BLADE
UNIT carefully.
Replace the Blade Unit
Maintenance
12