32
28 xx.xxF (C)
Displays the temperature near the final stage of the transceiver
If the temperature is about 50°F (10°C) or less, “LOWTMP” is displayed.
29 TOT
Set the timeout timer.
Set the transceiver to automatically return to receive mode after transmitting continu-
ously for a certain period of time. The TOT function limits inadvertent transmission of
unnecessary signals, and unwanted battery power consumption (time-out timer func-
tion).
OFF
The TOT time is deactivated.
1 MIN / 2 MIN
3 MIN / 5 MIN
10 MIN / 15 MIN
20 MIN / 30 MIN
Set the transceiver to automatically return to receive mode
after transmitting continuously for the set period of time.
The beep sounds at about 10 seconds before returning to receive mode automatically.
30 TX PWR
Select the transmit power output level
The transmit power can be reduced to save on energy consumption when communi-
cating with a nearby station.
HIGH
50W
MID
25W
LOW
5W
31 VER.DSP
Display the software versions of the transceiver.
Switch between “Main” and “Panel” by turning the
DIAL
knob.
M x.xx
The software versions of “Main” is shown.
P x.xx
The software versions of “Panel” is shown.
32 xx.xV
Indicates the DC Supply Voltage
33 WIDTH
Set the Modulation Level
The modulation can be set to half of its usual level. Select “WIDE” for normal amateur
operation.
WIDE
Normal transmit modulation level.
NARROW
Modulation is half of the normal level.