Page 142
FT
DX
9000D O
PERATION
M
ANUAL
M
ENU
M
ODE
102. SUB-RTTY-SLOPE
Function
: Selects the shape factor of the sub band
(VFO-B) DSP filter for the RTTY mode.
Available Values
: GENTLE/MEDIUM/STEEP
Default Setting
: MEDIUM
103. SUB-RTTY-NARROW
Function
: Selects the passband of the sub band
(VFO-B) DSP filter for the RTTY “narrow” mode.
Available Values
: 25/50/100/200/300/400 Hz
Default Setting
: 300 Hz
104. SUB-SSB-SHAPE
Function
: Selects the passband characteristics of
the sub band (VFO-B) DSP filter for the SSB mode.
Available Values
: SOFT/SHARP
Default Setting
: SHARP
SOFT:
Primary importance attached to amplitude
of the filter factor.
SHARP: Primary importance attached to phase of the
filter factor.
105. SUB-SSB-SLOPE
Function
: Selects the shape factor of the sub band
(VFO-B) DSP filter for the SSB mode.
Available Values
: GENTLE/MEDIUM/STEEP
Default Setting
: MEDIUM
106. SUB-SSB-NARROW
Function
: Selects the passband of the main band
(VFO-A) DSP filter for the “narrow” SSB mode.
Available Values
: 200/400/600/850/1100/1350/1500/
1650/1800/1950/2100/2250 Hz
Default Setting
: 1800 Hz
SCOPE G
ROUP
107. MAIN FIX 1.8 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the main
band (VFO-A) 160 m amateur band.
Available Values
: 1.800 - 1.999 MHz (1 kHz steps)
Default Setting
: 1.800 MHz
108. MAIN FIX 3.5 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 80 m
amateur band.
Available Values
: 3.500 - 3.999 MHz (1 kHz steps)
Default Setting
: 3.500 MHz
109. MAIN FIX 5.0 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 60 m
amateur band.
Available Values
: 5.250 - 5.499 MHz (1 kHz steps)
Default Setting
: 5.250 MHz
110. MAIN FIX 7.0 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 40 m
amateur band.
Available Values
: 7.000 - 7.299 MHz (1 kHz steps)
Default Setting
: 7.000 MHz
111. MAIN FIX 10 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 30 m
amateur band.
Available Values
: 10.100 - 10.149 MHz (1 kHz steps)
Default Setting
: 10.100 MHz
112. MAIN FIX 14 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 20 m
amateur band.
Available Values
: 14.000 - 14.349 MHz (1 kHz steps)
Default Setting
: 14.000 MHz
113. MAIN FIX 18 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 17 m
amateur band.
Available Values
: 18.000 - 18.199 MHz (1 kHz steps)
Default Setting
: 18.068 MHz
114. MAIN FIX 21 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 15 m
amateur band.
Available Values
: 21.000 - 21.449 MHz (1 kHz steps)
Default Setting
: 21.000 MHz
RX DSP G
ROUP
Summary of Contents for FT DX 9000D - COMPUTER AIDED TRANSCEIVER
Page 1: ...FTDX9000D Operation Manual...
Page 2: ......
Page 95: ...Page 93 FT DX 9000D OPERATION MANUAL NOTE...
Page 101: ...Page 99 FT DX 9000D OPERATION MANUAL NOTE...
Page 127: ...Page 125 FT DX 9000D OPERATION MANUAL NOTE...
Page 149: ...Page 147 FTDX9000D OPERATION MANUAL NOTE...
Page 152: ...Page 150 FTDX9000D OPERATION MANUAL NOTE...
Page 153: ...Page 151 FTDX9000D OPERATION MANUAL NOTE...