Page 137
FT
DX
9000D O
PERATION
M
ANUAL
M
ENU
M
ODE
SOFT
SHARP
SHARP
WIDE
MEDIUM
F
ILTER
P
ASSBAND
F
ILTER
S
HAPE
MODE-DAT G
ROUP
053. DATA IN SELECT
Function
: Selects the data input to be used on the
PKT mode.
Available Values
: DATA/PC
Default Setting
: DATA
DATA:Uses the data input line which is connected to
the rear panel’s
PACKET
jack while using the
PKT mode.
PC:
Uses the data input line which is connected to
the rear panel’s
AUDIO IN
jack while using the
PKT mode.
054. DATA GAIN
Function
: Sets the data input level from the TNC to
the AFSK modulator.
Available Values
: 0 ~ 255
Default Setting
: 128
055. DATA OUT
Function
: Selects the receiver to be connected to
the data output port (pin 4) of the
PACKET
jack.
Available Values
: VFO-a/VFO-b
Default Setting
: VFO-a
056. DATA VOX DELAY
Function
: Adjusts the “VOX” delay (receiver recov-
ery) time on the PKT mode.
Available Values
: 30 ~ 3000 msec
Default Setting
: 300 msec
057. DATA VOX GAIN
Function
: Adjusts the “VOX” gain on the PKT mode.
Available Values
: 0 ~ 255
Default Setting
: 128
MODE-FM G
ROUP
058. FM MIC GAIN
Function
: Sets the microphone gain for the FM mode.
Available Values
: MCVR/0 ~ 255 (FIX)
Default Setting
: 160
When this menu is set to “MCVR,” you may adjust
the microphone gain using the front panel’s
MIC
knob.
059. FM MIC SELECT
Function
: Selects the microphone to be used on the
FM mode.
Available Values
: FRONT/REAR/DATA/PC
Default Setting
: FRONT
FRONT: Selects the microphone connected to the
front panel’s
MIC
jack while using the FM
mode.
REAR: Selects the microphone connected to the
rear panel’s
MIC
jack while using the FM
mode.
DATA:
Selects the microphone connected to pin 1
of the
PACKET
Jack while using the FM
mode.
PC:
Selects the microphone connected to the
rear panel’s
AUDIO IN
3.5-mm jack while
using the FM mode.
060. RPT SHIFT
(
28MHz
)
Function
: Sets the magnitude of the repeater shift
on the 28 MHz band.
Available Values
: 0 ~ 1000 kHz
Default Setting
: 100 kHz
061. RPT SHIFT
(
50MHz
)
Function
: Sets the magnitude of the repeater shift
on the 50 MHz band.
Available Values
: 0 ~ 4000 kHz
Default Setting
: 1000 kHz
Summary of Contents for FT DX 9000D - COMPUTER AIDED TRANSCEIVER
Page 1: ...FTDX9000D Operation Manual...
Page 2: ......
Page 95: ...Page 93 FT DX 9000D OPERATION MANUAL NOTE...
Page 101: ...Page 99 FT DX 9000D OPERATION MANUAL NOTE...
Page 127: ...Page 125 FT DX 9000D OPERATION MANUAL NOTE...
Page 149: ...Page 147 FTDX9000D OPERATION MANUAL NOTE...
Page 152: ...Page 150 FTDX9000D OPERATION MANUAL NOTE...
Page 153: ...Page 151 FTDX9000D OPERATION MANUAL NOTE...