— 8 —
Device parameter
Value
Unit
Operating voltage (from an NMEA 2000 network)
7..16
V
Protection against reverse polarity
Yes
—
Consumption current of the Thermometer / Barometer
24 / 24
mA
Load Equivalency Number
1
LEN
Operating temperature range (except the Thermometer sensor) -40..+80
°С
Weight of the Thermometer / Barometer
31 / 11
g
NMEA 2000 data output resolution
0.01
°С / hPa
Parameters of the Barometer
Measurement range
300..1100
hPa
Relative measurement accuracy
± 0.12
hPa
Absolute measurement accuracy, at 0..+65 °
С
± 1
hPa
Absolute measurement accuracy in the rest of the range
± 2.5
hPa
Parameters of the Thermometer
Measurement range
-55..+125
°С
Error of the thermometer within the range of -10..+85°C, max
± 0.5
°
С
Error of the thermometer within the rest of the range, max
± 2
°
С
Summary of Contents for YDBC-05
Page 36: ...36 Figure 2 Digital sensor of the Thermometer...
Page 40: ......