Xylem Lowara LS Series Installation,Operation And Maintenance Instruction Download Page 17

Installation, Operating and Maintenance Instruction

                            Model LS, LC, LCP

 

 
 

 

LS 100-english

 

page 15

 

 

Artikel No. 771073402 

 

 

 

Re-lubrication via the two grease nipples (SN). 

 

6.5.3 Bearing temperature 

 

Bearing temperature (measured at bearing 
bracket) should lie max. 50°C over ambient 
temperature and must not exceed 90°C, control 
weekly at least. On grease lubrication the bearing 
temperature can temporarily be higher by 5-10°C 
after regreasing, till a possible surplus of grease in 
the bearings is cut. 

 

6.6 Monitoring 

 

 

In areas endangered to explosion it is 
recommended to monitor the temperature of the 
bearings and the vibrations of the bearing 
bracket.

 

 

 

Regular monitoring and maintenance will extend 
the life of your pump or pump system

.

 

 

 

Check oil level at least once a week and top up if 
necessary. 

 

Check pump for leaks at least once a week. 

 

On packing, check quantity of leakage at least 
once a week (see chapter 6.2 section "Packing"). 

 

Check the regulating and monitoring devices of 
any sealing, flushing or cooling systems once a 
week to ensure that they function properly. 
Outgoing cooling water should be hand warm. 

 

With double mechanical seals, monitor pressure 
and flow rate in mechanical seal area; check at 
least once a week. 

 

Pumps which are exposed to corrosive chemicals 
or to wear through abrasion must be inspected 
periodically for corrosion or wear and tear. The 
first inspection should be carried out after six 
months. All further inspection intervals should be 
determined on the basis of the state of the pump. 

 

6.7 Shutting down 

 

Close the valve in discharge pipe right before 
(max. 30 seconds) switching off the motor. This is 
not necessary if there is a spring-loaded check 
valve. 

 

Switch off motor (make sure it runs down quietly). 

 

Close the valve on suction side. 

 

Close auxiliary systems. Do not shut down cooling 
system until pump has cooled down. 

 

If there is any risk of freezing, empty pump, 
cooling areas and pipes completely. 

 

If the pump also remains under operating 
conditions (pressure and temperature) when 
stationary, leave all sealing, flushing and cooling 
systems switched on. 

 

The shaft sealing must remain sealed if there is a 
risk of air being sucked in (in the event of supply 
from vacuum systems or parallel operation with 
shared suction pipe). 

 

6.8 Storage / longer periods of non-
operation 

 

6.8.1 Storage of new pumps 

If the putting into operation shall happen a longer 
period after the delivery, we recommend the following 
measures for the storage of the pump: 

 

Store pump at a dry place. 

 

Rotate pump by hand at least once a month. 

 

6.8.2 Measures for longer putting out of operation 

Pump remains installed and in ready for operation: 

 

Test runs of 5 min. duration must be made in 
regular intervals. The span between the test runs 
is depending on the plant. However, it should be 
made once a week, at least. 

 

6.8.3 Longer periods of non-operation 

 

 

After long stationary periods, packing may have 
hardened; these must be replaced before start-
up. 
When starting up, follow the instructions for 
starting up for the first time (see chapter 6)!

 

 

a) Filled pumps 

 

Switch stand-by pumps on and immediately off 
again once a week. Possibly use as main pump. 

 

If the stand-by pump is at operating pressure and 
temperature, leave all sealing, flushing and 
cooling systems switched on. 

 

Replace oil or grease after 2 years. 

 

Stuffing box must be adjusted to maintain 
lubrication of the packing (e.g. do not over 
tighten). 

 

b) Drained pumps 

 

Turn shaft at least 1x week (do not switch on 
because of dry running). 

 

Replace oil or grease after 2 years. 

 

7. Servicing, Maintenance

7.1 General remarks 

 

 

Work should only be carried out on the pump or 
pump unit when it is not in operation. You must 
observe chapter 2.

 

 

 

Maintenance and servicing work must only be 
carried out by trained, experienced staff who 
are familiar with the contents of these Operating 
Instructions, or by the Manufacturer's own 
service staff.

 

 

 

Summary of Contents for Lowara LS Series

Page 1: ...920 en Volute Casing Pumps Model LS LC LCP Installation Operation and Maintenance Instruction Translation of the Original Operation Manual en Keep for further use Pay attention to this operating instr...

Page 2: ...Xylem Service Austria GmbH Ernst Vogel Stra e 2 A 2000 Stockerau Telefon 43 0 2266 604 Fax 43 0 2266 65311 E Mail info austria xyleminc com Internet www xylemaustria com...

Page 3: ...Handling Storage 9 4 1 Transport Handling 9 4 2 Storage Conservation 10 5 Mounting Installation 10 5 1 Mounting of Pump Unit 10 5 2 Connection of Pipings to the Pump 10 5 3 Coupling 11 5 4 Drive 12 5...

Page 4: ...ies to the manufacturer resp orders of spare ATEX Label only for pumps in compliance with EC directive 94 9 EG CE Marking of compliance with the EC directive 94 9 EG Ex specific marking for explosion...

Page 5: ...ir work during the guarantee period may only be carried out by us or subject to our written approval Otherwise the guarantee ceases to apply Longer term guarantees basically only cover correct handlin...

Page 6: ...danger to people or the environment The provisions of the law must be observed Measures should be taken to exclude any danger from electricity e g by complying with the local regulations on electrica...

Page 7: ...n t cause additional increase of surface temperature at the pump Furthermore the references in chapter 6 of these operating Instructions must be taken into consideration On pumps with mech seals the p...

Page 8: ...is is valid for the operation as well as for the standstill of the pump and therefore for all possible pressures and temperatures of the unit 2 8 3 NPSH The pumped liquid must have a min pressure NPSH...

Page 9: ...ng with barrier by pumped fluid P3 Packing with lantern ring with barrier by external fluid P4 Packing with lantern ring with flush P5 Packing without lantern ring with external cooling Position 4 Mat...

Page 10: ...76 0 75 5 76 5 76 5 90 0 77 0 76 5 77 5 77 5 110 0 78 0 77 5 77 0 79 0 78 5 80 0 132 0 79 0 78 5 78 0 79 5 79 5 80 0 160 0 80 0 79 5 79 0 80 5 81 0 80 5 200 0 81 5 81 0 80 5 81 5 82 0 83 0 250 0 82 5...

Page 11: ...200 6000 5400 6700 10450 3250 2300 2650 4800 200 400 250 8350 7450 6750 13050 4450 3150 3650 6550 200 6000 5400 6700 10450 3250 2300 2650 4800 200 500 250 8350 7450 6750 13050 4450 3150 3650 6550 200...

Page 12: ...ufficient firmness acc to DIN 1045 or equal standard min BN 15 to ensure a secure functional mounting The concrete foundation must have set before the unit is erected Its surface must be horizontal an...

Page 13: ...ed in the suction intake pipe when the motor is being started up If the pipe system is tested with the pump installed do not exceed the maximum permitted casing pressure of the pump and or shaft seali...

Page 14: ...available and correct if necessary Pay attention to chapter 6 beforehand It must be possible to turn the unit easily and harmoniously by hand Improper alignment of the unit can lead to damages at coup...

Page 15: ...ty devices are operational Switch on any sealing flushing or cooling devices that are provided See data sheet for quantity and pressure Open valve in suction intake pipe Set discharge side valve to ap...

Page 16: ...valid 6 5 Lubrication of Bearings 6 5 1 Oil lubrication The bearing bracket must be filled up with oil For quality of oil refer to chapter 7 4 1 For quantity of oil refer to chapter 7 4 1 The pumps a...

Page 17: ...ooled down If there is any risk of freezing empty pump cooling areas and pipes completely If the pump also remains under operating conditions pressure and temperature when stationary leave all sealing...

Page 18: ...ure 46 4 mm 2 s 175 C 15 C higher than permitted bearing temperature For ambient temperatures under 10 C another suitable type of lubrication oil must be used Request required Oil quantity Bearing bra...

Page 19: ...isassembled pumps units or single parts against tipping over or rolling off While disassembling the pump use of an open flame blowlamp etc only when there is no danger of setting fire cause an explosi...

Page 20: ...100S Unscrew the hexagon nuts M8 and demount the bearing cover 12 P Loosen and remove the hexagon screws S6 remove the bearing cover 12 Move the shaft 24 with the pair of angular contact bearings K2...

Page 21: ...ng the reverse order of steps as completed for pump disassembly However the following observations should be considered Pay attention to the utmost cleanliness when reassembling the pump For tight tol...

Page 22: ...arings aso 2 To ensure optimum availability we recommend that suitable quantities of spare parts are held in stock especially if these are made from special materials and in the case of mechanical sea...

Page 23: ...liquid level check if suction pipe is vacuum tight Air being sucked in through shaft sealing clean sealing pipe increase sealing pressure replace shaft sealing Direction of rotation is wrong swap ove...