VALUE: can represent a Speed or a Head, dependent from selected control mode.
In case of Head, the unit of measure is defined by parameter P41.
P05. Operating time months
It shows the amount of months of total operating time (drive supplied with power), to be added to
P06.
P06. Operating time hours
It shows the amount of hours of total operating time, to be added to P05.
P07. Motor Time Months
It shows the amount of months of motor operating time, to be added to P08.
P08. Motor time hours
It shows the amount of hours of motor operating time, to be added to P07.
P09. 1
ST
ERROR
It holds the last error happened. The information displayed switches through the values:
•
(Exx): xx reports the error code
•
(Hyy): yy is the value of hours referred to P05-P06 when the error Exx happened
•
(Dww):ww is the value of days referred to P05-P06 when the error Exx happened
•
(Uzz): zz is the value of weeks referred to P05-P06 when the error Exx happened
Example of visualization:
E04
→
K10
→
d03
→
U15
P10. 2
ND
ERROR
It holds the second error happened. The information displayed switches through the values:
•
(Exx): xx reports the error code
•
(Hyy): yy is the value of hours referred to P05-P06 when the error Exx happened
•
(Dww):ww is the value of days referred to P05-P06 when the error Exx happened
•
(Uzz): zz is the value of weeks referred to P05-P06 when the error Exx happened
See P09 for a visualization example.
P11. 3
RD
ERROR
It holds the third error happened. The information displayed switches through the values:
•
(Exx): xx reports the error code
•
(Hyy): yy is the value of hours referred to P05-P06 when the error Exx happened
•
(Dww):ww is the value of days referred to P05-P06 when the error Exx happened
•
(Uzz): zz is the value of weeks referred to P05-P06 when the error Exx happened
See P09 for a visualization example.
P12. 4
TH
ERROR
It holds the forth error happened. The information displayed switches through the values:
•
(Exx): xx reports the error code
•
(Hyy): yy is the value of hours referred to P05-P06 when the error Exx happened
•
(Dww):ww is the value of days referred to P05-P06 when the error Exx happened
•
(Uzz): zz is the value of weeks referred to P05-P06 when the error Exx happened
See P09 for a visualization example.
P13. Power Module Temperature
It shows the power module temperature, expressed in °C.
P14. Inverter Current
It shows the actual current sourced by the frequency converter, expressed in ampere.
P15. Inverter Voltage
It shows the actual estimated input voltage of the frequency converter, expressed in volt.