3.4 Motor technical data
Table 1: Electrical, Environmetal and Installation specifications
e-SM Drive model
103 105 107 111 115 303 305 307 311 315 322
Input
Input frequency [Hz]
50/60 ± 2
Mains supply
LN
L1 L2 L3
Nominal input voltage [V]
208÷240 ±10%
208÷240 / 380÷460 ±10%
380÷
460
±10%
Max. Input Current Continuous
[A]
2,3 3,3 4,4 6,3 8,6 - - - - - -
PDS Efficiency Class
IES2
Output
Min.÷Max. Speed [rpm]
800÷3600
Leakage Current [mA]
< 3,5
I/O au 15VDC power
supply [mA]
Imax < 40
Fault signal relay
1 x NO Vmax < 250 [VAC]
Imax < 2 [A]
2 x NO Vmax < 250 [VAC]
Imax < 2 [A]
EMC (Electro Magnetic
Compatibility)
See par.1.8 DECLARATION OF CONFORMITY
.
Installations must be done according to EMC good practice guidelines
(e.g. avoiding pigtails on drive side)
Sound Pressure LpA
[dB(A) @rpm]
<62 @3000
<66 @3600
Insulation class
155 F
Enclosure Rate
IP 55, Enclosure Type 1
Protect the product from direct sunlight and rainfall
Relative humidity RH (storage
& operating)
5% ÷ 95%
Storage temperature [°C (°F)]
-25÷
6
5 (-13÷1
49
)
Operating temperature [°C (°F)]
-20÷50 (-4÷122)
Air Pollution Degree
2
Altitude [m (ft)]
Max. 1000 (3280) above sea level.
For installation over 1000 (3280) above sea level de-rating may occur
3.5 Dimensions and weights
Reading instructions
Drawings show dimensions only in mm.
The images are not to scale.