background image

2

WARNING

Burn hazard. Heated oil can cause burns. 

Wear protective gloves, clothing and 

safety glasses during the oil change process. Failure to do so 

may result in personal injury.

ENGINE OIL CHANGE SYSTEM

Model 17850-1012

FEATURES

Pump Body:

    

Polypropylene

Diaphragm: 

   

*Geolast™, oil resistant

Valves: 

 

 

**Viton™, oil resistant

Motor: 

 

 

12V DC with integral power switch

Receiver: 

 

 

Plastic with 3.5 Gal. (13.2L)

 

 

(maximum) capacity bucket

Battery Leads: 

6 ft. (1.8m) with alligator clips

Suction Tube: 

 

8 ft. (2.4m) oil & heat resistant

Dimensions:

   

12-3/8” (314mm) diameter

 

 

12-3/4” (324mm) high

Weight (empty): 

 

6lbs. (2.7 kg)

OPERATING INSTRUCTIONS

1.  Run the engine for approximately 5 minutes to heat oil to 

approximately 160°F (71°C), then shut off engine prior to oil 
removal.

2.  Insert 1/4”(6mm) tube into pump inlet port and be sure that it 

is securely in place.

3.  Unscrew the pour spout to vent container prior to operating 

pump to allow air to vent.

4.  With the pump switch in the off position (to avoid sparks), 

clamp the power-leads’ alligator clips to a 12V DC battery (red 
to positive; black to negative).

5.  With the engine off, remove the dipstick, and insert the 

1/4”(6mm) oil change probe through the dipstick tube until it 
contacts the bottom of the oil pan. It may help to measure the 
probe against the dipstick, add an inch and mark the probe. 
Do not push the probe too far into the dipstick tube or it may 
curl up and out of the oil. It may be useful to tape the probe in 
place during evacuation.

6.  To evacuate the oil, switch on the pump using the rocker switch 

at the rear of the motor. Watch for flow in the probe. If no flow 
appears in 15 seconds, check the probe for sediment blockage. 
Clean the probe and reset it 1/4” (6mm) off the pan.

7.  The pump will speed up when the oil has been removed. An 

average 5 Quart (5 liters) oil capacity engine will take around 
10 minutes to drain.

8.  Switch off pump before removing alligator clips from the 

battery, to avoid sparks.

9.  Remove probe from dipstick tube while wiping with a rag to 

prevent oil drips.

10. To empty the container, pull up the retractable pour spout and 

pour the oil into a suitable container for disposal/recycling.

11. For extended storage, flush pump with water based degreaser 

solution.

NOTICE: Always recycle used oil in compliance with federal 

and local legislation. Handle petroleum products in an envi-

ronmentally responsible manner.

*Geolast is a registered trademark of Monsanto.
**Viton is a registered trademark of du Pont de Nemours & CO

Model 

Number

Voltage

Amp Draw

Fuse Size

17850-1012

12VDC

2A

5A

WARNING

Explosion hazard. Motor switch must be 

in “OFF” position when connecting and 

disconnecting alligator clips to battery terminal and ground. 

The swicth in an “ON” position can cause an electrical spark 

which can result in explosion. Injury or death can occur.

WARNING

Explosion hazard. Take necessary 

precautions to rid area around battery of 

potentially explosive gases. Continue ventilation during oil 

changing procedure. Failure to do so can result in explosion. 

Injury or death can occur.

WARNING

This system is not suitable for 

pumping gasoline.

Model 17850-1012

Summary of Contents for JABSCO 17850-1012

Page 1: ...LWECHSELSYSTEM BEDIENUNGSANLEITUNG SYSTEME DE VIDANGE DE L HUILE MOTEUR MANUEL D INSTRUCTIONS SISTEMA DI CAMBIO OLIO MOTORE MANUALE DI ISTRUZIONI VERVANGSYSTEEM MOTOROLIE HANDLEIDING SYSTEM F R BYTE A...

Page 2: ...evacuation 6 To evacuate the oil switch on the pump using the rocker switch at the rear of the motor Watch for flow in the probe If no flow appears in 15 seconds check the probe for sediment blockage...

Page 3: ...the engine s battery Red Positive Black Negative Remove the dipstick and insert the suction probe Activate pump with switch on motor to drain crankcase Replacement Parts Part Dipstick Hose 17867 0000...

Page 4: ...t l vacuation 6 Pour vacuer l huile mettez la pompe en marche l aide de l interrupteur bascule situ l arri re du moteur Surveillez l coulement dans la sonde Si aucun d bit n appara t dans les 15 secon...

Page 5: ...alimentation la batterie du moteur Rouge Positif Noir N gatif Retirez la jauge d huile et ins rez la sonde d aspiration Activez la pompe l aide de l interrupteur sur le moteur pour vidanger le carter...

Page 6: ...e nach 15 Sekunden noch kein Durchfluss erfolgen pr fen Sie nach ob die Sonde durch Ablagerungen verstopft ist Reinigen Sie die Sonde und ziehen Sie sie um 6 mm von der Wanne zur ck 7 Nach dem Absauge...

Page 7: ...rie Rot positiv Schwarz negativ Ziehen Sie den lmessstab heraus und f hren Sie die Absaugsonde ein Schalten Sie die Pumpe mit dem Schalter am Motor ein um das Kurbel geh use zu entleeren Ersatzteile A...

Page 8: ...uare l olio accendere la pompa con l interruttore a bi lanciere sul retro del motore Osservare il flusso nella sonda Se non appare alcun flusso dopo 15 secondi controllare la sonda per verificare se c...

Page 9: ...ia del motore Rosso Positivo Nero Negativo Rimuovere l asta di livello e inserire la sonda di aspirazione Azionare la pompa con l interruttore sul motore per scaricare il carter Parti di ricambio Nume...

Page 10: ...hakelaar aan de achterkant van de motor om de olie te ledigen Kijk uit voor stroming in de sonde Controleer de sonde op een blokkade door bezinksel als er binnen 15 seconden geen stroming verschijnt R...

Page 11: ...van de motor Rood positief Zwart Negatief Verwijder de peilstok en voer de zuigsonde in Schakel de pomp in met de schakelaar op de motor om de motorcarter te ledigen Vervangende onderdelen Onderdeel...

Page 12: ...mpen genom att anv nda vippstr mbrytaren bak p motorn Kontrollera fl det i sonden Om inget fl de syns inom 15 sekunder ska man kontrollera om det finns sedimentblockering Reng r sonden och s tt ter 6...

Page 13: ...t elsladdskl mmorna p motorns batteri R d positiv Svart negativ Ta bort oljestickan och f r in sugsonden Aktivera pumpen med brytaren p motorn f r att dr nera vevhuset Reservdelar Artikelnummer Oljest...

Page 14: ...il sujetar con cinta la sonda en su lugar durante la evacuaci n 6 Para evacuar el aceite encienda la bomba usando el inter ruptor basculante que est en la parte posterior del motor Observe si aparece...

Page 15: ...a la bater a del motor Rojo Positivo Negro Negativo Extraiga la varilla de medici n de aceite e inserte la sonda de aspiraci n Active la bomba con el interruptor del motor para drenar el c rter Piezas...

Page 16: ...Innovation Park London Road Harlow Essex CM17 9LX Xylem Inc AUSTRALIA 2 2 Capicure Drive Eastern Creek NSW 2766 Xylem Inc CHINA 30 F Tower A 100 Zunyi Road Shanghai 200051 www xylem com jabsco 2022 Xy...

Reviews: