e-SM Drive model
103
105
107
111
115
303
305
307
311
315
322
Operating
temperature
[°F] /[°C]
-4-122 / -20-50
Air Pollution
Pollution Degree 2
Installation
altitude a.s.l.
[ft] / [m]
< 3280 / 1000
Derating may occur at higher altitudes
9.2 Dimensions and weights
= =
B1
8.82 (224)
2.76 (70)
E1
3.15 (80)
4.61 (117)
8.82 (224)
2.91 (74)
6.10 (155)
E2
B5
5.87 (149)
B4
B5
2.68 (68)
0.91 (23)
B1
8.82 (224)
6.18 (157)
B4
10.91 (277)
4.92 (125)
4.92 (125)
0.75 (19)
B5
2.68 (68)
2.76 (70)
E1
= =
2.91 (74)
6.10 (155)
E2
B5
1~
3~
D3
D3
RS001945
Figure 9: Dimensions [in. (mm)]
9 Technical Specification
48
Smart Pump Range INSTRUCTION MANUAL