6.6 Software parameters
Mark
Parameter type
No mark
Applicable to all units.
G
Global parameter, shared by all pumps in the same
multi-pump system
Read only
6.6.1 Status parameters
Parameter number
Parameter name
Unit of measurement
Description
P01
Required value
bar/psi/ rpmx10
This parameter shows the
SOURCE and the VALUE of
the active required value.
Visualization cycles
between SOURCE and
VALUE occur every 3
seconds.
SOURCES:
• SP (SP): internal
required value Setpoint
related to the control
mode selected.
• VL (UL): external
required value speed
Setpoint related to
0-10V input.
VALUE can represent a
Speed or a Head,
depending on the selected
control mode:
in case of Head, the unit of
measure is defined by
parameter P41.
P02
Effective Required Value
bar/psi
Active required value
calculated based on
parameters P58 and P59.
This parameter is effective
only in control modes MSE
or MSY.
For further information on
the calculation of P02, see
Par. 6.6.3.
6 System Setup and Operation
30
Smart Pump Range INSTRUCTION MANUAL