code
Description
Cause
Remedy
E08
Power module temperature
error
Frequency converter
thermal protection trip
Check the conditions of
installation,and the air
temperature
E09
Generic hardware error
Hardware error
Stop the pump for 5
minutes and then restart it
again; if the problem
continues, contact Xylem or
the Authorised Distributor
E11
LOW error
Lack of water detection (if
P48= ERR)
Check the water level inside
the tank
E12
Pressure sensor error
Missing pressure sensor
(not present in ACT mode)
Check the condition of the
sensor connection cables
E14
Low pressure error
Pressure below minimum
threshold (not present in
ACT mode)
Check the settings of
parameters P45 and P46
E15
Loss of phase error
One of the three power
supply phases is missing
(three-phase versions only)
Check the connection to the
power supply network
E30
Multi-pump protocol error Incompatible multi-pump
protocol
Bring all the units to the
same firmware version
See also Par. 6.3.2 and Par. 6.4.3.