![Xylem FLYGT P7030 Series Installation, Operation And Maintenance Manual Download Page 71](http://html1.mh-extra.com/html/xylem/flygt-p7030-series/flygt-p7030-series_installation-operation-and-maintenance-manual_4106341071.webp)
WS003637A
2. Attach lifting straps as shown in the following figure, and lift the pump.
WS003666A
3. Place the drive unit upside down on the stand.
WS003638A
6.8 Replacing the propeller
Required tools:
• Stand 605 70 00
• 14 mm hexagon bit adapter with an extension bar
• Trim tool (17 mm hexagon bit adapter with an extension bar)
• Rod (wood or plastic) for locking the impeller in place.
CAUTION: Cutting Hazard
Worn parts can have sharp edges. Wear protective clothing.
6 Maintenance
P7030, P7035, P7040 Installation, Operation, and Maintenance Manual
69