WARNING: Crush Hazard
Make sure that the unit cannot roll or fall over and injure people or damage property.
NOTICE:
Do not run the pump dry.
NOTICE:
Never force piping to make a connection with a pump.
The pump is usually installed in a vertical discharge tube on a pump seat, which is
incorporated in the lower end of the tube. No anchoring is required because the weight of the
pump is sufficient to keep it in place. The pumps are equipped with anti-rotation devices.
WS001675A
Figure 8: Pump in the discharge tube. A generic propeller pump is shown.
4 Installation
P7030, P7035, P7040 Installation, Operation, and Maintenance Manual