![Xylem FLYGT P7030 Series Installation, Operation And Maintenance Manual Download Page 50](http://html1.mh-extra.com/html/xylem/flygt-p7030-series/flygt-p7030-series_installation-operation-and-maintenance-manual_4106341050.webp)
Item
Description
6
control element.
MAS 801: See the SIO manual for T1, T2,
and drain wire connections.
T2 cable lead (control element)
7
Screen (drain wire)
8
Power cable to unit
4.6.9 Cable bending radius, weight and diameter
Table 13: SUBCAB
®
Cable
Minimum bending
radius in mm
Weight in kg/m
Outer diameter,
minimum-maximum in
mm
4G4 + 2x1.5
200
0.63
Ø 20.0–22.0
4G6 + 2x1.5
240
0.83
Ø 24–26
4G10 + S(2x0.5)
240
0.85
Ø 24–26
4G16 + S(2x0.5)
260
1.13
Ø 26–28
4G25 + S(2x0.5)
320
1.70
Ø 32–34
4G35 + S(2x0.5)
350
2.24
Ø 35–37
3x50 + 2G35/2 + S(2x0.5)
350
2.6
Ø 35–37
3x70 + 2G35/2 + S(2x0.5)
380
3.3
Ø 38–41
Table 14: SUBCAB
®
screened cables
Cable
Minimum bending
radius in mm
Weight in kg/m
Outer diameter,
minimum-maximum in
mm
S3x6 + 3x6/3 + S(4x0.5)
200
0.55
Ø 20–22
S3x10 + 3x10/3 + S(4x0.5)
240
0.95
Ø 24–26
S3x16 + 3x16/3 + S(4x0.5)
240
1.1
Ø 24–26
S3x25 + 3x16/3 + S(4x0.5)
290
1.4
Ø 29–31
S3x35 + 3x16/3 + S(4x0.5)
320
2.0
Ø 32–34
S3x50 + 3x25/3 + S(4x0.5)
380
3.0
Ø 38–40
S3x70 + 3x35/3 +2 S(2x0.5)
420
3.5
Ø 42–44
4.7 Cable charts
Connection locations
The figures in this section illustrate how to interpret the connection strip symbols.
4 Installation
48