Table 7: Pt100 sensor
Description
Measured value
Fault values
The Pt100 sensor
is a resistor
changing value
almost linearly with
temperature.
Resistance:
• 100 ohm at 0ºC (32ºF)
• 107.79 ohm at room temperature
(20ºC, 68ºF)
• 138.5 ohm at 100ºC (212ºF)
For resistance data between 0–160 0ºC
(32–212ºF), see
on
page 84.
> 200 ohm (approx.) can indicate the
following situations:
• Broken sensor
• Bad contact
• Broken lead
< 70 ohm (approx) indicates:
• Short circuit.
NOTICE:
Never connect the Pt100 transducer to a voltage higher than 2.5 V.
For information on the various configurations of switches, thermistors and sensors used to
monitor stator winding temperature, see
Stator temperature monitoring methods
FLS
Table 8: Float switch sensor (FLS)
Description
Measured value
Fault values
The float switches are leakage
sensors.
Resistance. 2 sensor variants:
FLS:
• Normal: 1530 ohm
• Alarm: 330 ohm
FLS 10:
• Normal: 1200 ohm
• Alarm: 430 ohm
> 10% (approx.) deviation
from rated ohm values
indicates sensor fault, or fault
in the wiring.
VIS10
Table 9: Vibration sensor (VIS10)
Description
Measured value
Fault values
The vibration sensor located in
the junction box measures
vibrations in one direction. The
output is a 4-20 mA signal
proportional to the vibration
level.
Current, 4-20 mA
• >> 20 mA indicates a short circuit.
• << 4 mA indicates a fault.
• A zero value indicates a broken wire or bad
contact in a connector.
3.6.3 Stator temperature monitoring methods
The purpose of stator-winding temperature monitoring is to make the motor shut off at high
temperature. There are two monitoring methods, depending on the types of thermal sensors
chosen.
Table 10: Stator temperature monitoring configuration
Configuration with thermal switches
Configuration with thermistors
• Three thermal switches, connected in series, are
incorporated in the coil ends of the stator
winding. The switches are normally closed, and
open at 140°C (285°F).
• One Pt100 sensor is incorporated in one of the
windings.
• Three thermistors, PTC, connected in series, are
incorporated in the coil ends of the stator
windings. T
Ref
=140°C (285°F).
• One Pt100 sensor is incorporated in one of the
windings.
3 Product Description
P7030, P7035, P7040 Installation, Operation, and Maintenance Manual