Figure 12: Lower the pump to its final bottom position. A generic propeller pump is shown.
9. If the recommended cable handling system is used, then follow the instructions to finish
the cable connection. See the document "Installation, Operation and Maintenance, Flygt
Lift and Cable Handling System."
10.If the recommended cable handling system is not used, then fasten the power cables on
the cable holder and run them to the electric junction box.
Make sure that the cables have no sharp bends, are not pinched, and do not disturb the
water flow.
4.6 Make the electrical connections
4.6.1 General precautions
DANGER: Electrical Hazard
Before starting work on the unit, make sure that the unit and the control panel are isolated
from the power supply and cannot be energized. This applies to the control circuit as well.
WARNING: Electrical Hazard
Risk of electrical shock or burn. A certified electrician must supervise all electrical work.
Comply with all local codes and regulations.
WARNING: Electrical Hazard
There is a risk of electrical shock or explosion if the electrical connections are not correctly
carried out, or if there is fault or damage on the product. Visually inspect equipment for
damaged cables, cracked casings or other signs of damage. Make sure that electrical
connections have been correctly made.
4 Installation
P7030, P7035, P7040 Installation, Operation, and Maintenance Manual
37