7.5 Replace the impeller: P, S, T, Z installations
CAUTION: Cutting Hazard
Worn parts can have sharp edges. Wear protective clothing.
NOTICE:
When laying the pump on its side, do not allow the weight of the pump to rest on any
portion of the impeller. The impeller must not be allowed to make contact with the
concrete floor or other hard and rough surfaces.
1
2
3
4 5
6
7 8
WS009764B
1. Pump housing
2. Impeller
3. O-ring
4. Impeller screw
5. Washer
6. Clamping sleeve
7. Washers
Washers are not used for all configurations.
8. Screws
7.5.1 Remove the pump from the installation: T, Z installations
The pump must be removed from the installation before the impeller is replaced.
7 Maintenance
42
6020.180/090 Installation, Operation, and Maintenance Manual
Summary of Contents for FLYGT Concertor