Pump top
↓
Bearings
↓
Shaft unit
↓
Seals
↓
Impeller
↓
Discharge connection or cover
4.6.2 Install the stator
1
2
3
4
5
6
WS008547A
1. O-ring
2. O-ring
3. Stator housing
4. O-ring
5. O-ring
6. Stator
1. Place the stator on a support no wider than the stator.
Position the stator leads downwards in the stator.
2. Heat the stator housing to maximum 150°C (302°F).
3. Quickly lower the stator housing onto the stator until it bottoms.
Make sure the stator leads connection point is centered in the stator housing cable
throughlet.
4. Allow the stator housing and the stator to cool.
5. Guide the leads through the cable throughlet in the stator housing unit.
6. Fit new greased O-ring(s).