WS003038A
WS003064A
3. Remove the shaft assembly (shaft unit, bearing holder, bearings).
4.5.8 Remove the bearings
1. Remove the retaining ring.
2. Remove the bearing housing.
Use a press or the dismantling tool and make sure that the bearing housing is evenly
supported during the removal of the main bearing.
NOTICE:
Only use a puller with three claws. Otherwise, the bearing housing can be damaged.
WS002957A
Figure 10: Removing the bearing housing. Generic pump shown.
3. Remove the main bearing.
Use a press or the dismantling tool and make sure that the bearing housing is evenly
supported during the removal of the main bearing.
4 Maintenance
34
2640.181/.281 Service and Repair Instructions