WS008549A
6. Remove the fasteners securing the pump top.
The fasteners are located inside the pump top.
7. Remove the pump top and the O-ring under the pump top.
4.5.10 Disconnect the electrical connections
1
2
3
4
5
6
7
1
2
5
6
7
WS008546A
1. Incoming power
2. Ground (earth) leads
3. Starter unit
4. Leads between starter unit and terminal plate unit
5. Terminal plate unit
6. Stator leads
7. Stator
Figure 12: Configurations. Left: With starter unit. Right: Without starter unit.
1. Check that the power from the mains is physically disconnected and locked out.
2. Disconnect the power leads.
a) Configuration with starter unit: Disconnect the leads between the starter unit and
the terminal plate unit.
b) Configuration without starter unit: Disconnect the incoming power leads from the
terminal plate unit.
3. Disconnect the ground (earth) leads.
4. Configuration with starter unit: Remove the starter unit.
5. Remove the terminal plate unit.
4 Maintenance
36
2640.181/.281 Service and Repair Instructions
Summary of Contents for FLYGT 2640.181
Page 1: ...Service and Repair Instructions 885618_3 0 2640 181 281...
Page 2: ......
Page 70: ......
Page 71: ......