Suction cover
→
Impeller
→
Diffuser
→
Seal housing
↓
Stator with stator
house
←
Remove bearings
from bearing
housing
←
Rotor unit with
bearing housing
←
Seals
Dismantling to replace wear parts, seals and bearings
The following flowchart shows the general workflow when dismantling in order to access
the wear parts, seals and bearings.
Strainer
→
Suction cover
→
Impeller
↓
Seals
←
Seal housing
←
Diffuser
↓
Rotor unit with bearing
housing
→
Remove bearings from
bearing housing
4.5.2 Remove the discharge connection or cover
1. Place the pump in its upright position.
2. Remove the discharge connection (drainage pumps) or cover (sludge pumps).
WS008550A
3. Turn the pump upside down.
4.5.3 Remove the impeller: Drainage version
CAUTION: Cutting Hazard
Worn parts can have sharp edges. Wear protective clothing.
1. Remove the strainer.
4 Maintenance
2640.181/.281 Service and Repair Instructions
23
Summary of Contents for FLYGT 2640.181
Page 1: ...Service and Repair Instructions 885618_3 0 2640 181 281...
Page 2: ......
Page 70: ......